Install Entrapment Protection - Chamberlain CSL24U Installation Manual

Commercial вс vehicular slide gate operator
Table of Contents

Advertisement

To prevent SERIOUS INJURY or DEATH from a moving gate:
• ALL gate operator systems REQUIRE two independent entrapment
protection systems for each entrapment zone.
• Entrapment protection devices MUST be installed to protect anyone
who may come near a moving gate.
STEP 4

INSTALL ENTRAPMENT PROTECTION

This operator contains an inherent (internal) entrapment protection system and REQUIRES the addition of an external monitored entrapment
protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone prior to gate movement. A monitored
device sends a pulsed signal to the operator so the operator is aware of the device. If the operator does not receive the signal from the device it will
not run.
An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. Your
application may contain one or many entrapment zones. Property owners are obligated to test entrapment protection devices monthly. Use only
LiftMaster approved entrapment protection devices (refer to the accessory page).
NON-CONTACT SENSORS
If the photoelectric sensor beam gets blocked while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that
direction until the obstruction is cleared. Monitored photoelectric sensors MUST be used. If a monitored photoelectric sensor is not working or loses
power or the beam is blocked, then ALL gate operation in that direction will stop.
Sensors for Open Cycle
CONTACT SENSORS (EDGE SENSORS)
If the electrically activated edge sensor comes in contact with an obstruction while the gate is moving, the gate will stop and reverse. The gate will not
be able to travel in that direction until the obstruction is cleared.
Edge Sensor for Open Cycle
Edge Sensor for Open Cycle
INSTALLATION
• Locate entrapment protection devices to protect in BOTH the open
and close gate cycles.
• Locate entrapment protection devices to protect between moving
gate and RIGID objects, such as posts, walls, pillars, or columns.
Monitored Photoelectric Sensors
Edge Sensor for Close Cycle
14
Sensors for Close Cycle

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite series

Table of Contents