The alarms do not
Alarm contact not used
trigger
Error in alarms setting
The keyboard does not
The alarm contact setting cannot be
reset the alarms
reset by the keyboard.
There is no buzzer
Alarm buzzer disabled
when the alarm triggers
Make sure the Type of alarm is not: Not Used (set the alarm to N.O. or
N.C.)
For the alarm NO setting, make sure that, when there is an alarm, the alarm
pin closes with the common alarm pin. And for the alarm N.C. setting, make
sure that the alarm causes the common alarm and specific alarm pins to
open.
Change the alarm or alarm settings in question by entering the menu item:
Reset / Keyboard: YES.
Go to the Alarms menu and modify each individual alarm that is to trigger
the Buzzer (item Enable Buzzer: YES). The same holds for the alarm relay
(item Enable relay: YES).
Pag. 30
MNECKSVM164_0350