This guide provides brief explanations of options commonly used when displaying tomosynthesis images on the
SecurView DX workstation. For complete instructions, see the SecurView® DX/RT Workstation User Guide.
 To toggle between projection, MG, generated 2D, and reconstructed slices:
Click Projection to display projection images.
Click MG images to display conventional mammography or Hologic generated
2D images. Click repeatedly to switch between available mammography
images, if more than one image is available.
Click MG/Tomosynthesis Toggle to switch between mammography images
and reconstructed slices.
 To navigate reconstructed slices:
Click Reconstruction to display the slider tool. To select a slice:
• Click any location on the slider tool, or
• Move the slider handle, or
Reconstruction
• Rotate the scroll wheel on the mouse or keypad.
to Sequential or Advanced (one or several slices at a time).
 To use Cine mode:
• Click Cine or press the Cine button on the workflow keypad.
• Adjust speed with speed controller.
• Click Cine Boundary to hide speed controller. Click Cine Boundary again to
Cine
restore.
 To stop Cine mode:
• Click Cine again, press the Cine button, or rotate mouse or keypad scroll
wheel.
 To start Local Cine mode:
• Press and hold Cine on the workflow keypad, or
• Click and hold Cine on the display, or
• Press
Cine
 To change the Local Cine center slice:
• While Local Cine mode is running, rotate the mouse wheel or keypad scroll
wheel.
 To stop Local Cine mode:
• Click Cine again, press the Cine button or press
 To change the number of displayed slices (slab thickness):
• To display the V-Split cursor, point mouse at the slab thickness bar (see
above), then click and drag up or down.
• To reset, double-click the slab thickness bar.
Tip: With a user preference, you can set the mouse/keypad wheel mode
Tip: Set the default speed with a user preference.
[F6]
on the keyboard.
Tip: Set the Local Cine slice range with a user preference.
Tip: Set the default slab thickness with a user preference.
SecurView
DX Tomosynthesis Imaging
®
Projection MG Images
[F6]
.
Quick Reference Guide
Reconstruction
MG/Tomosynthesis
Orientation
(H, F, L, M)
Slider Handle
Slab Thickness
Bar
Boundary
Speed Controller
Slab Thickness
V-Split Cursor
MAN-04945 Revision 003, Page 1 of 2
Cine
Toggle

Advertisement

loading
Need help?

Need help?

Do you have a question about the SecurView DX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hologic SecurView DX

  • Page 1 Quick Reference Guide This guide provides brief explanations of options commonly used when displaying tomosynthesis images on the SecurView DX workstation. For complete instructions, see the SecurView® DX/RT Workstation User Guide.  To toggle between projection, MG, generated 2D, and reconstructed slices:...
  • Page 2 © 2017 - 2019 Hologic Inc. Printed in the USA. This manual was originally written in English. Hologic, SecurView, and associated logos are trademarks and/or registered trademarks of Hologic, Inc., and/or its subsidiaries in the United States and/or other countries.