6 SHIELDING GAS RECOMMENDATION

6
SHIELDING GAS RECOMMENDATION
Welding
Shielding Gas Material
MAG
Mix Ar/CO
MAG
Mix Ar/CO
MIG
100% Ar
FCAW
Mix Ar/CO
FCAW
100% CO
FCAW
Mix Ar/CO
FCAW
100% CO
TIG DC
100% Ar
TIG DC
100% Ar
TIG DC
100% Ar
TIG AC
100% Ar
A general rule to be followed for shielding gas flow rate is 10 to 12 times of wire size. It may
increase for different welding applications where higher stick out and parameters are used.
When using Helium mixtures, the flow rate must be 1.5 to 3 times more than with argon.
0463 730 231
Carbon steel
2
Stainless steel
2
Aluminium
Carbon steel
2
Carbon steel
2
Stainless steel
2
Stainless steel
2
Carbon steel
Stainless steel
Stainless steel
Aluminium
Recommended Flow Rate (l/min)
Wire Ø × 10
Wire Ø × 10
Wire Ø × 12
Wire Ø × 12
Wire Ø × 12
Wire Ø × 12
Wire Ø × 12
Cup size or nozzle number × 1.2
Cup size or nozzle number × 1.2
Cup size or nozzle number × 1.2
Cup size or nozzle number × 1.2