5 OPERATION
NOTE!
Be sure not to lose the key located on the drive motor shaft. This key must be in place and
aligned with the drive roll slot for proper operation.
5.8
Shielding gas
The choice of suitable shielding gas depends on the material. Typically mild steel is welded with mixed
gas (Ar + CO
) or 100% carbon dioxide (CO
2
(Ar + CO
). Aluminum can be welded with argon gas (Ar) and silicon bronze can be welded with use
2
pure argon gas (Ar) or (Ar + O
5.9
Duty cycle
The Rogue EM 180 has a welding current output of 180 A at 25% duty cycle (230 V). A self-resetting
thermostat will protect the power source if the duty cycle is exceeded.
If the power source operates at a 25% duty cycle, it will provide the rated amperage for a maximum of
2.5 minutes out of every 10-minute period. The remaining time, 7.5 minutes, the power source must
be allowed to cool down.
3 minutes
A different combination of duty cycle and welding current can be selected.
0447 979 001
). Stainless Steel can be welded with mixed gas
2
).
2
- 21 -
7 minutes
© ESAB AB 2023