Download Print this page
Johnson Pump Viking Power 32 Instruction Manual

Johnson Pump Viking Power 32 Instruction Manual

Advertisement

Quick Links

Instruction Manual
Viking Power 32
Viking Power Vacuum
12/24 V DC
IB-117 R01 (0512)

Advertisement

loading

Summary of Contents for Johnson Pump Viking Power 32

  • Page 1 Instruction Manual Viking Power 32 Viking Power Vacuum 12/24 V DC IB-117 R01 (0512)
  • Page 2 Viking Power 16 mounted to dc motor 12/24 V Please follow all instructions before attempting an installation. Typical applications Working principle Viking Power 3/Vacuum is the ideal dia- Single-chamber, self-priming diaphragm phragm pump for toilet drain, wastewater pump. To obtain good self-priming ability and bilge pumping.
  • Page 3 NOTE: Before installation with electrical Pressure and capacity data control systems, check that equipment to Pressure Flow Amp. draw be used is of sufficient rated capacity to ac- Bar kPa Psi L/min USGPM 12V 24V cept amperage draw of motor. Low voltage 34.4 can cause the motor to overheat.
  • Page 4 Self-priming Service instructions The pump is self-priming up to ,5 and 5 m respectively (Viking Power Vacuum) change of diaphragm dry running 1. Remove the two screws that hold the The pump can be run dry without any clamps and remove the clamps. harm.
  • Page 5: Troubleshooting

    Troubleshooting Symptom cause Solution 1. The pump doesn’t run. 1.1 Tripped thermal protector 1.1.1 Check the fuse. Let the or blown fuse. motor cool down before restart if it is overheated. 1. Faulty wire connection or 1..1 Check the battery/power power supply.
  • Page 6 JP-1400/02 (03/2009)
  • Page 7 JP-1400/02 (03/2009)

This manual is also suitable for:

Viking power vacuum