Cylindrical Lockset
Installation Instructions
Miscellaneous Options
12
e
CLX3329 Hotel Function Timing Adjustment
Timing of the hotel cylinder is set at the factory for the standard door thickness. If the change key or emergency key does not
operate properly, follow the steps below:
1. Set the lock to the unlocked position, remove lever and cylinder from the outside trim. See lever removal instruction on
page 4).
2. Insert adjustment tool (provided with lock) into interior cap located within the shank (Figures 22 & 23).
3. Rotate cap clockwise until fully tight (Figure 24).
Figure 22
4. Rotate cap back counter-clockwise (Figure 25) until tool handle is approximately in line with the end of the shank as shown
in Figure 26 for Fixed Core cylinder (FC) or in Figure 27 for Interchangeable Cylinder (LFIC). The flat on the tool should be at
the 12 o'clock position.
Figure 25
5. Install cylinder in the lever (see cylinder installation instruction on page 3).
6. Turn key 90 degrees counter-clockwise and install lever (with cylinder) onto shank.
7. Test to confirm that both the operating and the emergency keys work properly in both the unlocked and locked (pushed/
pushed and turn) positions.
- If the operating key is still working in the locked position, the interior cap needs to be turned out (CCW) 1/2 turn.
- If the emergency key is not working in the locked position, the interior cap needs to be turned in (CW) 1/2 turn.
Troubleshooting:
- If having issue fine tuning the adjustment, re-start from #3.
- If cylinder will not install, re-start from #3.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com • www.corbinrusswin.com
Pour le français, visiter: www.corbinrusswin.com/en/library/installation-instructions.
Copyright © 2021, 2022, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.
Reproduction in whole or in part without the express written permission of ASSA ABLOY Access
and Egress Hardware Group, Inc. is prohibited.
Interior Cap
Adjustment Tool
Flat on Tool
Figure 23
End of Shank
Figure 26
WARNING
This product can expose you to lead
which is known to the state of California
to cause cancer and birth defects or other
reproductive harm. For more information go
to www.P65warnings.ca.gov.
Figure 24
Figure 27
FM566-EN 6/22