Sanitary systems TECEone TECHNICAL INFORMATION...
Page 2
All data contained in the Technical Information has been compiled with the utmost care. However, the correctness of the data presented cannot be guaranteed. TECE assumes no liability for damage resulting from the use of this information. Text and images are protected by copyright law.
Contents Introduction System description Functions Technical data Dimensions Approval and certificates Operation Planning and assembly Water connection device Mounting the toilet ceramic Temperature adjustment Mounting the toilet seat Cleaning and Maintenance Faults Servicing and spare parts...
Without using the shower function, it can also be used as a conventional toilet ceramic. TECEone not only shines with inner values, it looks pretty good too! Thanks to its timeless, elegant design, it can be easily integrated into any bathroom ambience and com- bined with the existing bathroom equipment.
Operation is intuitive. TECE relies on proven technology in this area. The EN 1717-compliant safeguard is integrated in the TECEone, so the product no longer needs to be safe- guarded separately. Shower arm By turning the rotary knob, the shower arm automatically...
(right picture). Controls • You can increase or reduce the volume of water by turn- TECEone is operated intuitively using the right and left ing the right rotary knob until you achieve the required rotary knobs: result.
Planning and assembly Planning and assembly Water connection device warm kalt TECEone is operated with fresh hot and cold water from cold the pipe. Corresponding upgrade sets are available for chaud froid caliente frio installing and precisely positioning the water connections...
Page 8
Planning and assembly 13 mm max. 7 Nm! Attach the sound insulation strips to the back of the Secure it with the concealed fitting (13 mm ratchet) from ceramic. the underside of the toilet ceramic. Observe the maximum torque of 10 Nm. <...
If the measured temperature is not higher than 38°C, you do not need to do anything else and can use the TECEone immediately. However, if the measured water temperature is higher than 38°C, follow the steps below to adjust the temperature.
Page 10
Planning and assembly Place the stop in the “up” position on the toothed shaft. Turn the toothed shaft until the two red marks are aligned. 0° > 38 °C ≤ 38 °C Fit the cap holding fixture onto the toothed shaft until it Now open the water volume rotary knob and measure the reaches the stop (scald protection).
Cleaning and Maintenance Mounting the toilet seat 60° TECEone must always be combined with the TECEone seat with lid. The toilet seat and lid fixings are already in place and immovably cast with the ceramic. 60° Turn the cap holding fixture up to the left stop, then turn it 60°...
Cleaning and Maintenance Cleaning and Maintenance Faults The TECEone has been designed in such a way that prob- Lid and toilet seat, rotary knobs lems are extremely unlikely and may only occur in very few Clean the lid, toilet seat and rotary knobs every day using cases.
Servicing and spare parts Servicing and spare parts TECE relies on tried-and-tested technology. However, should components ever need to be replaced or serviced, you will find the spare parts for TECEone below. 9, 10, 11, 12 Item no. Description 9820357...
Need help?
Do you have a question about the TECEone and is the answer not in the manual?