Honeywell NOTIFIER NFS2-640 Manual page 39

Hide thumbs Also See for NOTIFIER NFS2-640:
Table of Contents

Advertisement

Module
AEM-32A
AFM-16A
AFM-16AT
AFM-32A
AKS-1
RKS-S
ACM-24AT
AEM-24AT
ACM-48A
AEM-48A
FDU-80
LCD-80
LCD-80TM
LCD2-80
RPT-W
RPT-F
RPT-485W
RPT-485FW
FFT-7
FFT-7S
FHS
FPJ
NBG-12LX
NBG-12LRA
RM-1, RM-1SA
BP2-4
FCO-851
FSA-8000
FSA-20000P
KEY:
Y = Yes
N = No
O = Optional
Notes:
1.
The system must contain either one or the other displays.
2.
The system must contain at least one of the units.
3.
When used with the DAA, DAA2, DAX or DS-DB, the system must use the NCA-2/C or the NCD as the display.
4.
Each unit must include at least one enclosure.
5.
Various dress panels/dead fronts/ trim rings must be employed so that internal components and high voltage is not accessible.
6.
Also required when devices for Carbon Monoxide signaling are employed.
7.
.Required if utilizing a central station other than supported by CGW-MB
• Alarm verification (maximum verification period of 60 for field programmable between 0 and 60s)
• Supports standard 2-wire smoke detectors using Models FZM-1. refer to the Device Compatibility Document for compatible 2-wire smoke detectors
• Supports addressable or analog devices
• Field Programming
• Signal Silence Inhibit
• Remote annunciator outputs
• Automatic Alarm Signal Silence
• Drift compensation
• Detector sensitivity testing per Par. 7-3.2.1 of NFPA 72GW-MB alone OR using a CGW-MB with CGW-PT OR using CGW-DACT.
8.
Required when using CGW-MB alone OR using a CGW-MB with CGW-PT OR using CGW-DACT.
NFS2-640 UL Listing Document — P/N 52741LD:H9 5/19/2022
Description
Annunciator Expander Module
Annunciator Fixed Module
Annunciator Fixed Module
Annunciator Fixed Module
Annunciator Key Switch
Remote Security Keyswitch
Annunciator Control Module
Annunciator Expander Module
Annunciator Control Module
Annunciator Expander Module
Annunciator
Annunciator
Annunciator
Annunciator
Repeater Wire
Repeater Fiber
Repeater Wire
Repeater Wire/Fiber
Firefighter's Telephone
Firefighter's Telephone
Fireman's Handset
Fireman's Phone Jack
Addressable Manual Pull Station
Agent Release Abort Station
Remote Microphone
Battery Plate
PLUS Multi-Criteria Fire/CO
IntelliQuad
Detector
Intelligent Aspiration Detector
Intelligent Aspiration Detector
Table 12 System Configuration (3 of 3)
CS
Local
AUX
RS
P (PPU) P(Burg) REL P Rec
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Y
Y
Y
Y
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Y
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Y
Y
Y
Y
O
O
O
O
O
O
O
O
O
O
O
O
Process
Mana.
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Y
O
O
O
39