4.2 Installation hollow shaft encoder
► Place the clamping nut on the encoder
► Slip the encoder onto the shaft (min 10 mm) and fix the stator coupling by
means of one M3 screw
► Tighten the screws of the clamping nut
► Connect encoder and drive by means of a flexible coupling
> Avoid damage to the shaft and the bearing
► In case of linear measurement with a measuring wheel, encoder and
measuring wheel should be mounted on the end of a flexible arm

5 Electrical connection

The unit must be connected by a qualified electrician
The national and international regulations for the installation of electrical
equipment must be adhered to
► Disconnect power
► Connect the device according to the indications on the type label
5.1 Laying the cable
• Extension by means of a screened extension cable; max length 100 m
► lay separately from sources of interference (minimum spacing 02 m)