External View; Example Of System Configuration - Mitsubishi Electric PAC-YG66 DCA-J Installation Instructions Manual

Table of Contents

Advertisement

4-2. External View

5

Example of System Configuration

Power supply unit
PAC-SC50KUA
G-50A or GB-50A
LAN
or
System remote controller,
ON/OFF remote controller,
Schedule timer
G(B)-50A Web or
TG-2000A
Note:
• For the shield ground of the M-NET centralized control line, use single-point grounding at the power unit for the transmission
line.
However, when supplying electric power to the M-NET centralized control line from the R410A series outdoor unit without using
a power supply unit for the transmission line, use single-point grounding at the TB7 of that outdoor unit.
Furthermore, when connecting this device to the M-NET indoor control line, use grounding at the TB3 for each outdoor unit
system.
• If this device is connected to the M-NET indoor control line and the outdoor unit is down because, for example, the power supply
is interrupted for servicing or there is a failure, the DIDO controller cannot be controlled from the system controller.
• Controlling the system remote controller, ON/OFF remote controller, and schedule timer is only possible with channel 1 of a
standard terminal.
• When G(B)-50A is connected, monitoring control can only be performed from G(B)-50A Web or TG-2000A. Monitoring control
cannot be performed from the system remote controller, ON/OFF remote controller or schedule timer.
52 ( 2
This device complies with Part15 of the FCC Rules.Operation is
subject to the following two conditions: (1)this device may not cause
harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
[ Expansion
I/O ]
Ch5,Ch6
Ch3,Ch4
26 ( 1
)
1
/
32
Centralized control line
M-NET
M-NET
DIDO controller
(a) (b)
(c) (d)
Ventilation fan,
lighting, etc.
* This figure omits the power supply line and only shows the transmission line.
111 ( 4
)
3
/
8
200 ( 7
)
7
/
8
150 ( 5
)
29
/
32
)
46.5 ( 1
)
1
/
27
/
4.5
16
32
(
)
3
/
16
DIDO controller
PAC-YG66DCA
[ OUTPUT ] Transistor Output
24 VDC
[ OUTPUT ] Non-voltage Contact Output
[ Junction Terminal ]
Ch1
Ch2
Ch1
Ch2
ON/OFF,(ON)
(OFF)
ON/OFF,(ON)
(OFF)
ON/OFF,(ON)
(OFF)
ON/OFF,(ON)
(OFF)
[ Output LEDs ]
Ch1
Ch2
ON/OFF
(OFF) ON/OFF
(OFF)
(ON)
(ON)
N623
DIDO
controller
MODEL
PAC-YG66DCA
SERVICE REF. PAC-
YG66MCA-J
INPUT
VOLTAGE
DC24V;0.2A
WEIGHT
0.6 kg / 1 /
3 8
lb
SERIAL No.
MADE IN JAPAN
[ INPUT ]
[ 24 VDC Power Supply]
Ch1
Ch2
ON/OFF
Error
ON/OFF
Error
83.5 ( 3
)
27 ( 1
)
5
/
3
/
16
32
(a) ON/OFF, (ON) output
(b) (OFF) output
(c) ON/OFF input
(d) Error/Normal input
Standard: Terminal block (for 2 units)
Expansion: Connectors (for 4 units)
<Restrictions>
Maximum of 50 units (50 channels) per G(B)-50A
However, the number of units that can be connected to a G(B)-50A is
up to 50 including the number of contacts used on this device, an
indoor unit, Lossnay unit, etc.
Indoor control line
City Multi
(a) (b)
Ventilation fan,
lighting, etc.
24 VDC
Power supply
× up to 6 units
3
45 ( 1
)
25
/
32
(
)
9
3
/
8
Unit: mm (in)
Total: 6 units
DIDO controller
(c)
(d)
× up to 6 units
24 VDC
Power supply

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pac-yg66dca

Table of Contents