Veris Industries E31 Series Installation Manual page 8

Branch circuit power meter with split-core cts
Table of Contents

Advertisement

E31 Series Installation Guide
Data Outputs (cont.)
Z205667-0G
Page 8 of 23
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
• Signed power factor: By default the E31 reports power factor as an unsigned value. The user can set it to report as a
signed value, where the sign indicates whether the current phase angle leads or lags the corresponding voltage phase.
• Demand/snapshot time interval source: The E31 offers two mechanisms for driving the demand/snapshot time
interval, an interval timer or an RTC (real-time clock). The legacy mode (default) uses an interval timer that does not
need to be set to an absolute time. When using the interval timer the demand/snapshot interval can be set from
10 to 32767 seconds (over 9 hours). An alternate mode utilizes an RTC set to a specific date and time to synchronize
the results with a larger system. The RTC must first be set in order to run and capture demand values and energy
snapshots. When power is interrupted, the RTC resets to a default date and time and must be set again in order to run.
When using the RTC, the demand/snapshot interval can be set from 10 to 3600 seconds (1 hour).
Monitoring of Mains
Current: multi-phase average and per phase
Current phase angle
Real power (kW): multi-phase total and per phase
Apparent power (kVA): multi-phase total and per phase
Real Time Measurements
Power factor: multi-phase average and per phase
Voltage - L-L: multi-phase average and per phase
Voltage - L-N: multi-phase average and per phase
Frequency (phase A)
Current present demand: multi-phase average and per phase
Demand Measurements
Real Power (kW) present demand: multi-phase average and per phase
Maximum instantaneous current: multi-phase average and per phase
Maximum current demand: multi-phase average and per phase
Historic Maximums
Maximum real power demand: multi-phase total and per phase
Accumulated Energy
Energy (kWh): multi-phase total and per phase
Energy Snapshots
Energy (kWh): multi-phase total and per phase
Monitoring of Branch Circuits
Current: multi-phase average and per phase
Current phase angle per branch
Real power (kW): multi-phase total and per phase
Real Time Measurements
Apparent power (kVA): multi-phase total and per phase
Power factor: multi-phase average and per phase
Current present demand: multi-phase average and per phase
Demand Measurements
Real power (kW) present demand: multi-phase average and per phase
Maximum instantaneous current: multi-phase average and per phase
Maximum current demand: multi-phase average and per phase
Historic Maximums
Maximum real power demand: multi-phase total and per phase
Accumulated Energy
Energy (kWh): multi-phase total and per phase
Energy Snapshots
Energy (kWh): multi-phase total and per phase
Voltage over/under
Branch current over/under
Alarms
Mains current over/under
©2015 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
Modbus Alarms
TM
E31A
E31B
E31C
0815