QUICK START GUIDE
Water Resistant RFID Access Control Reader
Applicable Model: ProlD Series
Version: 1.1
Date: March 2023

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco ProlD Series

  • Page 1 QUICK START GUIDE Water Resistant RFID Access Control Reader Applicable Model: ProlD Series Version: 1.1 Date: March 2023...
  • Page 2: Product Overview

    1.Product Overview ProID 0.4" (11.0mm) 1.8"(44.5mm) Indicator Mounting Buzzer Hole Switch ProID 0.5" (11.6mm) 3.4"(86.0mm) Indicator Mounting Buzzer Hole Switch...
  • Page 3 ProID 0.5" (11.6mm) 3.0"(76.0mm) Indicator Mounting Buzzer Hole Switch Back Plate 1.4"(36.0mm) 3.1"(80.0mm) Tamper Tamper Switch Switch 2.4"(60.0mm) 0.5" (12.8mm) 0.5" (13.0mm) ProID101 ProID102...
  • Page 4: Terminal Block

    2.9"(73.0mm) 2.4"(60.0mm) Tamper Switch 0.5" (13.0mm) ProID103 2.Terminal Block +12V Power RS485A RS-485 RS485B Wiegand Out Wiegand 26/34 WG26/34 Beep BEEPER Red LED RLED Green LED GLED Tamper TAMPER...
  • Page 5: Device Installation

    3.Device Installation Install on the wall ① Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. ② Secure the back plate on the wall with the wall mounting screws. ③ After passing the wires through the wiring hole and connecting them to the device, and then attach the device to the back plate from top to bottom.
  • Page 6 Mounting on the wall through Asian gang box ① Install the Asian gang box (or single gang box, mullion mount) into the wall. ② Fix the back plate onto the Asian gang box (or single gang box, mullion mount) using two wall mounting screws. ③ Pass the cables through the wire hole.
  • Page 7: Dip Switch Settings

    4.DIP Switch Settings As shown in the table below, places 1-3 of the DIP switch are used to set the device number for RS-485 communication, and place 4 is for setting the RS485 termination resistance. If the RS-485 communication wire is longer than 100 meters, it is needed to set the 4th DIP switch of the last reader to ON state, that is parallel a terminal resistance of 120 ohm between 485+ and 485-.
  • Page 8: Controller Connection

    6.Controller Connection This ProlD series reader needs to be connected to a host machine in order to transmit card information via RS-485 or wiegand. The following is an example of the connection to InBio Series controller. Connect the controller via RS485...
  • Page 9 Connect the controller via Wiegand BEEPER GLED InBio Series Conttroller +12V WG26/34 STATE ProlD Series Reader RS485 RS485 READER1 Note: SWITCH When terminal WG26/34 is connected to TCP/IP Router ground, the number of Wiegand output bits is 26 bits. The default is not grounded, and the number of Wiegand output bits is 34 bits.
  • Page 10: Power Connection

    8.Tamper Switch Connection When the tamper switch terminal is successfully connected to the controller, the device will sound an alarm when the back plate of the device is opened, and an alarm signal will be sent to the software side. +12V RS485A RS485B...
  • Page 11: Specifications

    10.Buzzer, Indicator Light Prompt Instructions When the ProlD series reader works normally, the buzzer and indicator prompts are shown in the following table. Buzzer Working Status Indicator Light LED bright white light, When the reader is then switch to white light 1 short sound powered on.
  • Page 12 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 : +86 755 - 89602394 www.zkteco.com Copyright © 2023 ZKTECO CO., LTD. All Rights Reserved.