TIMER TO CLOSE FEATURE (TTC)
24
Door may operate unexpectedly, therefore
do not allow anything to stay in the path
of the door.
The Timer to Close feature requires The Protector SystemTM (IR
Beams) to be installed.
Operation:
This feature allows the door to automatically close from a fully open
position after a specified time. The delay can be set from 10 to 180
seconds in 10 second increments, by using the opener control buttons.
If the door encounters an obstruction while closing, the door will stop
and return to the UP position. The Courtesy lamp will then flash 10
times.
To Activate TTC, or change a preset time:
1.
Start with the door fully CLOSED.
2.
Enter into TTC Activation mode by pressing both PROG and
DOWN buttons together for 3 seconds (figure 2). Release when the
courtesy light flashes twice.
3.
Press the UP button once for each 10 second increment required
of TTC (figure 3. eg. twice for 20 seconds). Press the DOWN arrow
to reduce, if needed.
4.
Press and release the PROG button to save this time
(figure 4), courtesy light will flash once. TTC is now activated.
TEST: Operate the door to the UP position. Keep clear of the IR Beams
and check the door closes after the preset time.
To Deactivate TTC:
1.
Enter into TTC Activation mode by pressing both PROG and
DOWN buttons together for 3 seconds (figure 2). Release when the
courtesy light flashes twice.
2.
Press and release the PROG button to save (figure 4), courtesy
light will flash once. TTC is now deactivated.
INSTALLING YOUR E148M FOUR BUTTON WIRELESS WALL MOUNT REMOTE CONTROL
25
NOTE: The wall control supplied with your opener should be pre-programmed by the factory.
If adding a new wall control, program into the opener before mounting the unit as detailed in Wireless Programming.
Disconnect power to the opener before installing this
accessory to prevent accidental activation. Locate
minimum 1.5 m above the floor.
To install:
Carefully pry open the E148M and locate the two screws for
mounting.
Attach to the wall using the two screws provided. If mounting
to a plaster wall, wall plugs may be required.
NOTE: Do not overtighten screws.
Replace the front cover plate.
PROGRAMMING
figure 1
figure 2
figure 3
figure 4
figure 5
15
Indicator LED
Door Fully Closed
Indicator LED
Indicator LED
Indicator LED
or
1
2

Advertisement

Table of Contents
loading

Table of Contents