Merlin CYCLONE PRO MT120EVO Installation And Operating Instructions Manual

Merlin CYCLONE PRO MT120EVO Installation And Operating Instructions Manual

Sectional garage door opener

Advertisement

gomerlin.com.au
gomerlin.co.nz
MT120EVO
Sectional Garage Door Opener
Installation and Operating Instructions
Owners Copy: SAVE THESE INSTRUCTIONS for future reference
This manual contains IMPORTANT SAFETY information
DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY

Advertisement

Table of Contents
loading

Summary of Contents for Merlin CYCLONE PRO MT120EVO

  • Page 1 gomerlin.com.au gomerlin.co.nz MT120EVO Sectional Garage Door Opener Installation and Operating Instructions Owners Copy: SAVE THESE INSTRUCTIONS for future reference This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY...
  • Page 2: Table Of Contents

    These safety alert symbols mean WARNING : A possible risk to personal safety or property damage exists. Merlin recommends that “The Protector System ” be installed on all garage door openers. The “Protector Keep garage door balanced.
  • Page 3: Before You Begin

    BEFORE YOU BEGIN: 1. Look at the wall and ceiling above the garage door. (The opener and header bracket must be securely fastened to structural supports.) 2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may be required.
  • Page 4: Carton Inventory

    CARTON INVENTORY Your garage door opener and rail are packed in two seperate cartons. The CyclonePro (MT120EVO) opener carton contains the opener, its fitting hardware and accessories. The rail carton contains the rail and some hardware. (1) Opener (9) Hardware bag (2) Hand held transmitter (2) (10) Rail assembly (separate carton) (3) Wireless wall control...
  • Page 5: Tools Required

    TOOLS REQUIRED Drill Bits HARDWARE PROVIDED (1) Clevis pin 80 mm (2) R clip (3) Hexagonal head screw 3 (4x) 1 (1x) 2 (1x) 4 (4x) (4) Nut M8 (5) Flat washer M8 5 (4x) (6) Clevis Pin (7) R clip 8 (4x) 7 (1x) 9 (8x)
  • Page 6: Control Panel

    Common terminal for push button Ground White Common terminal for IR Beams IR Sensor Gray Merlin IR Beam Input: (pulsing type only) Door-in-door Green For Door in Door dry contact sensor: (4&5 are normally linked) Door-in-door Green Common terminal for Door in Door sensor...
  • Page 7: Assembly

    ASSEMBLY SECTION ASSEMBLING THE RAIL TO THE OPENER Your garage door opener and rail are packed in two separate cartons. Remove the Power Head, Rail and all the hardware in preparation for assembly. The chain is pretensioned from the factory, however, it is advisable to check the tension and adjust if necessary as outlined in step 9.
  • Page 8: Installation

    INSTALLATION SECTION Wear protective goggles when working overhead to protect your eyes from injury. Disengage all existing garage door locks to avoid damage to the garage door. To avoid serious personal injury from entanglement, remove all ropes connected to the garage door before installing the opener.
  • Page 9: Sectional Door

    POSITION THE OPENER Disengage the trolley mechanism (see section “Operating the manual release”) and slide it back towards the powerhead. Secure the hanging push arm up into the rail assembly temporarily using tape or rope, to avoid a hazard. SECTIONAL DOOR You will need a 50 mm piece of timber or similar spacer to gauge the distance between door and rail.
  • Page 10 HANG THE OPENER The opener must be securely fastened to a sound structural support above the opener. fig.1 1.Postion the opener as in the previous step. Check the rail is centred over the door. Ensure the rail brackets (fig.1) is on the Powerhead end of the rail in a position as close to the opener as possible (X).
  • Page 11: Operate The Manual Release

    Make sure the garage door is fully closed. Pull the manual release ATTACH DOOR ARM TO TROLLEY cord to disengage the trolley. Slide the trolley to around 300 mm Fig. 1 from the header bracket. Fig. 2 1.The straight door arm is already preassembled to the trolley. 2.Install the curved arm onto the door bracket using the Clevis pin (2) and R-Clip (3) supplied.
  • Page 12: Adjustment

    ADJUSTMENT SECTION Travel limits regulate the points at which the door will stop PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS Without a properly installed safety reversal when moving UP or DOWN. The travel limit buttons are located system, persons (particularly small under the access cover on the rear panel (figure 1).
  • Page 13 TEST THE SAFETY REVERSE SYSTEM The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing garage door.
  • Page 14: Install The Protector System (Optional)

    400 N (40 kgf). To prevent entrapment, install The Protector SPECIAL NOTE: Merlin strongly recommends that The Protector System be installed on all garage door System™ no higher than 100 mm above the floor.
  • Page 15: Button

    TIMER TO CLOSE FEATURE (TTC) Door may operate unexpectedly, therefore do not allow anything to stay in the path of the door. figure 1 The Timer to Close feature requires The Protector System (IR Beams) to be installed. Indicator LED Operation: Door Fully Closed This feature allows the door to automatically close from a fully...
  • Page 16: Install Warning Labels

    INSTALL WARNING LABELS figure 1 For Service Call RISK OF ENTRAPMENT Installation Date Repeat Safety Reverse Test monthly. Door 114A3361 must reverse on contact with a 40mm obstacle For Service Call placed on the floor. Make necessary adjustments. AUTOMATIC DRIVE: Keep away from the area of the door since it may operate unexpectedly.
  • Page 17: Wireless Programming

    WIRELESS PROGRAMMING (OPTIONAL ACCESSORIES) Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave garage while door is in motion. Do not allow children to operate push button(s) or remote(s). Do not allow children to play near the door.
  • Page 18: Using Your Opener

    MAINTENANCE AND CARE OF YOUR OPENER Battery of the remote control: USING YOUR OPENER REPLACE BATTERIES IN REMOTES 1. Your opener can be activated by any of the following devices: • Opener control panel: Up and Down Buttons and Green O.S.C. The batteries in the remote have an extremely long life.
  • Page 19: Accessories

    E138M E128M E945M E1702M 760E E840M 774ANZ NOTE: Only genuine Merlin accessories are approved for use with this opener. Generic compatible accessories are NOT approved for use with this opener. REPLACEMENT PARTS 004C5600 041A4038 Hardware bag Pulley assembly 002A1850 Trolley with rope &...
  • Page 20: Replacement Parts

    REPLACEMENT PARTS If the supply cord is damaged, it must be Power Cord replaced by the manufacturer, its service 026B0181 agent or similarly qualified persons in order to avoid hazard. 041A1847 Logic Board / PCB Housing / Control Cover (assembly) 041A4004 Passpoint Assembly...
  • Page 21: Troubleshooting

    TROUBLE SHOOTING 1. Opener doesn't operate from either door control or 7. Door opens but won't close: remote: • Check The Protector System™ (if you have installed • Does the opener have electric power? Plug lamp into this accessory). If the light on the Beams are flashing, outlet.
  • Page 22: Diagnostic Chart

    DIAGNOSTIC CHART Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage opener flash the diagnostic codes. DIAGNOSTIC CODE SYMPTOM POSSIBLE RESOLUTION UP Arrow DOWN Arrow Flash(es) Flash(es) The garage door opener will not Safety sensors are not installed, connected or wires may be cut.
  • Page 23: Specifications

    SPECIFICATIONS - CyclonePro - MT120EVO Input Voltage......230-240 Vac, 50 Hz Max. Pull Force ......1200 N Power ........225 Watt Standby Power ......0.8 Watt (door fully closed) Normal Torque ......8 Nm Max door weight......286 kgs Max lift under spring tension ..20 kg Max door area......Residential Sectional Doors up to 20 m Motor Type...........DC gearmotor permanent lubrication...
  • Page 24: Warranty

    What is covered Chamberlain warrants to the original purchaser of the Merlin CyclonePro 6 water or moisture ingress that causes corrosion or electrical malfunction; MT120EVO Sectional Door Opener (Unit) that all parts of the Unit, other than 7 corrosion caused by sea air if located near a waterway, beach etc;...