TECHNICAL PRECAUTIONS

• Operating temperature: 0°C to +40°C (+32°F to +104°F)
• The video image may distort when the door release is activated. But this
is not a unit malfunction.
• If a zoom/wide or pan/tilt operation is performed during communica-
tion with the entrance station, noise will be produced at the entrance
station, but this is not a malfunction.
• Cleaning: Clean the units with a soft cloth dampened with a neutral
household cleanser. Do not use any abrasive cleaner or cloth.
12

SPECIFICATIONS

• Power supply:
DC 24 V (from power supply)
• Current consumption:
GT-2C-L: (MAX) Approx. 390mA
GT-2H-L: (MAX) Approx. 240mA
GT-2C: (MAX) Approx. 260mA
GT-2H: (MAX) Approx. 110mA
• Communication:
Hands-free communication/
Press-to-talk communication
• Video monitor:
3-1/2" TFT color LCD
• Dimensions:
140 (H) × 190 (W) × 30 (D) (mm)
5-1/2 (H) × 7-1/2 (W) × 1-1/4 (D) (inches)
• Weight:
GT-2C-L: Approx. 520 g (1.15 lbs.)
GT-2C: Approx. 470 g (1.04 lbs.)
GT-2H-L: Approx. 480 g (1.06 lbs.)
GT-2H: Approx. 440 g (0.97 lbs.)
• If there is a system malfunction, unplug the power supply and contact a
qualified technician for service.