Measure the distance between the
two cross-shaped mounting holes.
Drill two holes with a diameter of 6 mm (0.24 in) and depth of 25 mm (0.98 in) in the wall.
Hammer a screw anchor into each hole. Use a Phillips screwdriver to drive the screw into
each screw anchor, leaving 1.5 mm (0.06 in) between the screw head and the wall for
hanging the switch.
1
2
25 mm
(0.98 in)
Connecting the grounding cable
Correctly connecting the grounding cable is crucial to lightning protection and EMI protection. Use the
grounding cable provided with the switch for grounding.
Mark the installation holes on the wall. Make
sure the two installation holes are on the same
horizontal line
3
1.5 mm
(0.06 in)
Connect the grounding cable to the switch
Installing a power module
This section is applicable only to switch models that use removable power modules.
Remove a filler panel (skip this step if no filler panel is in the power module slot)
Connecting the power cord
For switch models with removable power modules, make sure the power modules are installed
correctly before connecting a power cord.
Before connecting the power cord, make sure the switch is reliably grounded.
To avoid bodily injury, connect the power cord first to the switch and then to the equipment-room
power supply system.
The number of cable ties and installation positions of the cable ties (if provided) depend on the
switch model.
The power cord varies by power module. Do not mix power cords.
Method 1
1
Connect the grounding cable to a grounding strip
2