KROHNE OPTITEMP TT 12 R Quick Start Manual
KROHNE OPTITEMP TT 12 R Quick Start Manual

KROHNE OPTITEMP TT 12 R Quick Start Manual

Programmable 2-wire transmitter for pt100 / pt1000 and thermocouple

Advertisement

Quick Links

Quick Start
OPTITEMP TT 12 R
Programmable 2-wire transmitter
For Pt100 / Pt1000 and Thermocouple
Installation, assembly, start-up and maintenance may only be performed by appropriately trained personnel.
Check the nameplate for correct operating conditions.
This instrument complies with requirements of Low Voltage Directive. Instruments must not be connected to
power supply before reading instructions described in the manual.
The responsibility as to the suitability, intended use and corrosion resistance of the used materials against
the measured fluid of this device rests solely with the operator.
1 Installation
OPTITEMP TT 12 R RTD - Temperature converter for resistance sensor
OPTITEMP TT 12 R TC - Temperature converter for thermocouples
The TT 12 R RTD / TT 12 R TC is designed to be mounted on a 35 mm DIN Rail
according to EN 60715 / DIN 50022.
Connect input, output and power supply according to "Electrical connection".
The transmitter is configured from a mobile device via NFC
OPTICHECK Temperature Mobile. The app is avaiable for free download on App Store and
Google Play™.
Ambient temperature
T
min.
Transmitter
[°C]
TT 12 R RTD
-40
TT 12 R TC
Factory settings
TT 12 R RTD
Pt100 3W, 0 to 100 °C
Input
(equivalent to 212 °F)
Output
4 to 20 mA
Filtering level
Response time 0.9 s
Sensor error indication
Upscale
12/2021 – 4009159301 – QS OPTITEMP TT 12 R RTD/TC R02 en
communication, by using the app
TM
T
max.
[°F]
[°C]
[°F]
-40
+85
+185
TT 12 R TC
Type K, 0 to 1000 °C
(equivalent to 1832 °F)
4 to 20 mA
Response time 0.9 s
Upscale
For initial set up, we strongly recommend that you also refer to the relevant manual!
Springcage connection
The cable is connected using a spring-cage connection.
In order to minimize measuring errors ensure that
the cable is securely fastened.
1. Insert a screwdriver into the opening above the
connection terminal block.
(Use a 2.5 x 50 mm slotted screwdriver.)
2. Insert the wire into the corresponding
connection terminal block.
Mounting and removal of the transmitter
1. Fix the upper part of the transmitter onto the rail.
2. Press the lower part of the transmitter against the rail.
3. To remove the transmitter, bend the locking device using a small screwdriver. Carefully pull
the transmitter in the forward direction.
1

Advertisement

loading

Summary of Contents for KROHNE OPTITEMP TT 12 R

  • Page 1 Response time 0.9 s 3. To remove the transmitter, bend the locking device using a small screwdriver. Carefully pull Sensor error indication Upscale Upscale the transmitter in the forward direction. 12/2021 – 4009159301 – QS OPTITEMP TT 12 R RTD/TC R02 en...
  • Page 2 Select your country from the region / language selector to [Ω] = (U-6)/0.022 following code and enter the serial number. Load view your local KROHNE contact details on: www.krohne.com Supply voltage U (VDC) 12/2021 – 4009159301 – QS OPTITEMP TT 12 R RTD/TC R02 en...