Clear And Sanitize Procedures; Non-Volatile And Volatile Memory Device Table Terminology; Memory Devices - Tektronix 4 Series Declassification And Security Instructions

Mixed signal oscilloscopes
Hide thumbs Also See for 4 Series:
Table of Contents

Advertisement

Clear and sanitize procedures

Non-volatile and volatile memory device table terminology

The tables in this section use the following terms:
User data. Describes the type of information stored in the device. Refers to waveforms or other measurement information representing
signals connected to the instrument by users.
User settings. Describes the type of information stored in the device. Refers to instrument settings that can be changed by the user.
Both. Describes the type of information stored in the device. It means that both user data and user settings are stored in the device.
None. Describes the type of information stored in the device. It means that neither user data or user settings are stored in the device.
Directly. Describes how data is modified. It means that the user can modify the data.
Indirectly. Describes how data is modified. It means that the instrument system resources modifies the data and that the user cannot
modify the data.

Memory devices

The following tables list the volatile and non-volatile memory devices in the instrument.
Volatile memory devices
These are the memory capacities at the time of publishing this document, but are subject to change.
Type and
Function
Type of
size
user info
stored
SDRAM 4
Host
User data No
GB (All
processor
models)
memory
SDRAM
Holds active
User data No
MSO44: 4
acquisition
GB
data
MSO46: 8
GB
SDRAM
Holds video
User data No
512 MB
graphics
data
CMOS
Holds clock
None
RAM 7
and boots
bytes
configuration
data
FPGA <30
Interface
None
MB
between
compute
system and
acquisition
system
4 Series Mixed Signal Oscilloscopes Declassification and Security Instructions MSO44, MSO46
Backed-
Method of
Data input
up by
modification
method
battery
Indirectly
Written by
processor
system
Indirectly
Application
software
operations
Indirectly
Application
software
operations
Yes
Indirectly
boot
operations
No
None
Written by
processor
system
Clear and sanitize procedures
Location
User
To clear
acce-
ssible
Processor
No
Unplug the
board
instrument for at
least 30
seconds
Module
No
Unplug the
socket
instrument for at
(SODIMM)
least 30
on the
seconds
Acquisition
board
Acquisition
No
Unplug the
board
instrument for at
least 30
seconds
Processor
No
Cannot be
board
cleared
Acquisition
No
Unplug the
board
instrument for a
minimum of 30
seconds
To sanitize
Unplug the
instrument for at
least 30
seconds
Unplug the
instrument for at
least 30
seconds
Unplug the
instrument for at
least 30
seconds
Unplug the
instrument for a
minimum of 30
seconds
Unplug the
instrument for a
minimum of 30
seconds
5