Sign In
Upload
Manuals
Brands
Tektronix Manuals
Test Equipment
DPO4104
Tektronix DPO4104 Manuals
Manuals and User Guides for Tektronix DPO4104. We have
6
Tektronix DPO4104 manuals available for free PDF download: User Manual, Instruction Manual, Demo Instruction Manual, Technical Reference, Instructions Manual
Tektronix DPO4104 User Manual (359 pages)
Digital Phosphor Oscilloscopes. MSO4000 series; DPO4000 series
Brand:
Tektronix
| Category:
Test Equipment
| Size: 3.67 MB
Table of Contents
Table of Contents
7
General Safety Summary
13
Compliance Information
16
EMC Compliance
16
Safety Compliance
18
Environmental Considerations
21
Preface
22
Key Features
22
Where to Find more Information
24
Conventions Used in this Manual
26
Installation
27
Before Installation
27
Operating Considerations
34
Connecting Probes
39
Securing the Oscilloscope
42
Powering on the Oscilloscope
42
Powering off the Oscilloscope
45
Functional Check
46
Compensating a Passive Voltage Probe
49
Application Module Free Trial
51
Installing an Application Module
52
Changing the User Interface Language
53
Changing the Date and Time
56
Signal Path Compensation
59
Upgrading Firmware
62
Connecting Your Oscilloscope to a Computer
69
Connecting a USB Keyboard to Your Oscilloscope
78
Get Acquainted with the Instrument
79
Front-Panel Menus and Controls
79
Front-Panel Connectors
103
Side-Panel Connector
104
Rear-Panel Connectors
105
Acquire the Signal
107
Setting up Analog Channels
107
Using the Default Setup
115
Using Autoset
116
Acquisition Concepts
117
How the Analog Acquisition Modes Work
120
Changing the Acquisition Mode, Record Length, and Delay Time
122
Using Roll Mode
125
Setting up a Serial or Parallel Bus
126
Setting up Digital Channels
149
When and Why to Turn on Magnivu
154
Using Magnivu
155
Trigger Setup
156
Triggering Concepts
156
Choosing a Trigger Type
163
Selecting Triggers
165
Triggering on Buses
172
Checking Trigger Settings
182
Using Sequence Trigger (a (Main) and B (Delayed))
183
Starting and Stopping an Acquisition
186
Display Waveform Data
187
Adding and Removing a Waveform
187
Setting the Display Style and Persistence
188
Setting Waveform Intensity
194
Scaling and Positioning a Waveform
195
Setting Input Parameters
198
Positioning and Labeling Bus Signals
205
Positioning, Scaling, and Grouping Digital Channels
207
Viewing Digital Channels
211
Annotating the Screen
212
Viewing the Trigger Frequency
214
Analyze Waveform Data
216
Taking Automatic Measurements
216
Selecting Automatic Measurements
218
Customizing an Automatic Measurement
225
Taking Manual Measurements with Cursors
233
Using Math Waveforms
239
Using FFT
242
Using Advanced Math
246
Using Reference Waveforms
248
Using Wave Inspector to Manage Long Record Length Waveforms
250
Analyzing Power
260
Save and Recall Information
262
Saving a Screen Image
266
Saving and Recalling Waveform Data
268
Saving and Recalling Setups
273
Saving with One Button Push
276
Printing a Hard Copy
278
Erasing Oscilloscope Memory
289
Using Application Modules
292
Application Examples
295
Taking Simple Measurements
295
Analyzing Signal Detail
308
Triggering on a Video Signal
317
Capturing a Single-Shot Signal
323
Correlating Data with a TLA5000 Logic Analyzer
328
Tracking down Bus Anomalies
330
Troubleshooting Circuits Using Parallel Buses
335
Troubleshooting an RS-232 Bus
339
Appendix: Warranted Specifications
345
Advertisement
Tektronix DPO4104 User Manual (268 pages)
Digital Phosphor Oscilloscopes
Brand:
Tektronix
| Category:
Test Equipment
| Size: 2.57 MB
Table of Contents
Table of Contents
5
General Safety Summary
9
Environmental Considerations
12
Preface
14
Key Features
14
Where to Find more Information
16
Conventions Used in this Manual
17
Installation
19
Before Installation
19
Operating Considerations
24
Connecting Probes
28
Powering on the Oscilloscope
29
Powering off the Oscilloscope
32
Functional Check
33
Compensating the Probe
35
Installing an Application Module
37
Changing the User Interface Language
38
Changing the Date and Time
41
Signal Path Compensation
43
Upgrading Firmware
46
Connecting Your Oscilloscope to a Computer
52
Get Acquainted with the Instrument
63
Front-Panel Menus and Controls
63
Using the Menu System
64
Using the Menu Buttons
67
Identifying Items in the Display
77
Front-Panel Connectors
84
Side-Panel Connector
85
Rear-Panel Connectors
86
Acquire the Signal
88
Setting up Signal Input
88
Using the Default Setup
91
Using Autoset
92
Acquisition Concepts
93
Waveform Record
95
How the Acquisition Modes Work
96
Changing the Acquisition Mode and Record Length
98
Using Roll Mode
101
Defining a Serial Bus
102
Trigger Setup and Run
109
Triggering Concepts
109
Trigger Modes
110
Trigger Holdoff
111
Trigger Coupling
112
Slope and Level
114
Choosing a Trigger
116
Selecting Triggers
117
Triggering on Buses
120
Checking Trigger Status
125
Using a (Main) and B (Delayed) Triggers
125
Starting and Stopping an Acquisition
129
Display Waveform Data
130
Adding and Removing a Waveform
130
Setting the Display Style and Persistence
130
Setting Waveform and Graticule Intensity
133
Setting the Graticule Style
135
Setting the LCD Backlight
136
Scaling and Positioning a Waveform
138
Setting Input Parameters
140
Analyze Waveform Data
147
Taking Automatic Measurements
147
Selecting Automatic Measurements
149
Customizing an Automatic Measurement
155
Taking Manual Measurements with Cursors
162
Using Math Waveforms
168
Using FFT
171
Using Advanced Math
175
Using Reference Waveforms
178
Managing Long Record Length Waveforms
181
Save and Recall Information
192
Saving a Screen Image
192
Saving and Recalling Waveform Data
194
Saving and Recalling Setups
202
Saving with One Button Push
205
Printing a Hard Copy
207
Erasing DPO4000 Memory
214
Use Application Modules
218
Application Examples
219
Taking Simple Measurements
219
Measuring Two Signals
224
Customizing Your Measurements
228
Analyzing Signal Detail
235
Looking at a Noisy Signal
236
Separating the Signal from Noise
239
Taking Cursor Measurements
241
Triggering on a Video Signal
244
Capturing a Single-Shot Signal
248
Optimizing the Acquisition
251
Using the Horizontal Zoom Function
252
Correlating Data with a TLA5000 Logic Analyzer
253
Tracking down Bus Anomalies
256
Tektronix DPO4104 Instruction Manual (132 pages)
Demo 2 Board
Brand:
Tektronix
| Category:
Test Equipment
| Size: 1.62 MB
Table of Contents
Table of Contents
5
Getting Started with the MSO/DPO2000, MSO/DPO3000, and MSO/DPO4000 Series Oscilloscopes
7
Gettingstartedwiththemso/Dpo2000 ,Mso/Dpo3000,Andmso/Dpo4000Seriesoscilloscopes
8
Demo I: Acquiring a Signal
8
Demo II: Using Vertical Controls
12
Demo III: Using Horizontal Controls
14
Demo IV: Using Run/Stop Controls
15
Demo V: Using Trigger Controls
15
Demo VI: Using Cursors
18
Demo VII: Taking Measurements
20
Demo VIII: Saving a Screen Image
23
Giving Demos of Advanced Oscilloscope Features
27
Overall Package
27
MSO/DPO4000 Series Performance
28
MSO/DPO3000 Series Performance
29
MSO/DPO2000 Series Performance
30
Wave Inspector Demos
31
Demo IX: Setting up I 2 C Signals
32
Demo X: Using the Wave Inspector's Zoom and Pan Functionality
37
Demo XI: Using the Wave Inspector's Search Functionality
43
Demo XII: Using Serial Triggering and Analysis
48
Demo XIII: Searching Serial Signals
61
Demo XIV: Monitoring and Decoding RS-232 Signals
65
Demo XV: Triggering on a Serial Data Pattern (E.g. RS-232)
73
Demo XVI: Filtervu (MSO/DPO2000)
76
Giving Demos of MSO Features
85
Ease of Use
85
Performance
85
Tour the MSO Front Panel
87
Demo XVII: Setting up Digital Channels (MSO2000, MSO3000, and MSO4000 Models)
88
Demo XVIII: Discovering Per-Channel Thresholds (MSO4000 Only)
95
Demo XIX: Labeling Channels (MSO2000, MSO3000, and MSO4000 Models)
97
Demo XX: Exploring Parallel Buses (MSO2000, MSO3000, and MSO4000 Models)
99
Demo XXI: Triggering on Parallel Bus Data Values (MSO2000, MSO3000, and MSO4000 Models)
105
Demo XXII: Searching for Parallel Bus Data Values (MSO2000, MSO3000, and MSO4000 Models)
108
Demo XXIII: Zooming in on White Edges (MSO4000 Only)
110
Troubleshooting
117
Locating Signals
118
Advertisement
Tektronix DPO4104 Demo Instruction Manual (109 pages)
4000 Series
Brand:
Tektronix
| Category:
Test Equipment
| Size: 1.78 MB
Table of Contents
Table of Contents
3
Getting Started with the Tektronix 4000 Series
5
Demo I: Acquiring a Signal
6
Demo II: Using Vertical Controls
9
Demo III: Using Horizontal Controls
11
Demo IV: Using Run/Stop Controls
12
Demo V: Using Trigger Controls
12
Demo VI: Using Cursors
15
Demo VII: Taking Measurements
17
Demo VIII: Saving a Screen Image
20
Giving Demos of Advanced Tektronix 4000 Features
24
Overall Package
24
Performance
25
Wave Inspector Demos
26
Demo IX: Setting up I2C Signals
27
Demo X: Using the Wave Inspector's Zoom and Pan Functionality
33
Demo XI: Using the Wave Inspector's Search Functionality
39
Demo XII: Using Serial Triggering and Analysis
44
Demo XIII: Searching Serial Signals
55
Demo XIV: Monitoring and Decoding RS-232 Signals
59
Demo XV: Triggering on a Serial Data Pattern (E.g. RS-232)
67
Giving Demos of MSO4000 Features
70
Ease of Use
70
Performance
70
MSO4000 Demos
72
Demo XVI: Setting up Digital Channels
73
Demo XVII: Discovering Per-Channel Thresholds
80
Demo XVIII: Labeling Channels
81
Demo XIX: Exploring Parallel Buses
83
Demo XX: Triggering on Parallel Bus Data Values
88
Demo XXI: Searching for Parallel Bus Data Values
91
Demo XXII: Discovering Multi-Channel Setup and Hold
93
Demo XXIII: Zooming in on White Edges
100
Operating the Demo Board
106
Operating the Board
107
Troubleshooting the Demo Board
108
Tektronix DPO4104 Technical Reference (59 pages)
Digital Phosphor Oscilloscopes Specifications and Performance Verification
Brand:
Tektronix
| Category:
Test Equipment
| Size: 0.74 MB
Table of Contents
Table of Contents
5
General Safety Summary
7
Table 1: Analog Channel Input and Vertical Specifications
9
Specifications
9
Table 2: Digital Channel Input Specifications, MSO4000 Only
15
Table 3: Horizontal and Acquisition System Specifications
15
Table 4: Trigger Specifications
15
Table 5: Display Specifications
21
Table 6: Input/Output Port Specifications
21
Table 7: Power Source Specifications
21
Table 8: Data Storage Specifications
22
Table 9: Environmental Specifications
22
Table 10: Mechanical Specifications
23
Table 11: P6516 Digital Probe Specifications
24
Performance Verification
25
Upgrade the Firmware
25
Test Record
27
Performance Verification Procedures
43
Table 12: Maximum Bandwidth Frequency Worksheet
47
Table 13: Gain Expected Worksheet
50
Tektronix DPO4104 Instructions Manual (13 pages)
4000 Series Declassification and Security
Brand:
Tektronix
| Category:
Test Equipment
| Size: 0.25 MB
Table of Contents
Table of Contents
3
Preface
5
Clear and Sanitize Procedures
7
Memory Devices
7
Data Export Devices
8
Built-In Security Features
9
When to Use Teksecure
9
What Teksecure Does
9
Disable the LAN Port and Clear LAN Ethernet Settings
10
Disable the USB Device Port
11
Clear and Sanitize a Non-Functional Instrument
13
Advertisement
Related Products
Tektronix DPO4104B
Tektronix DPO4104B-L
Tektronix DPO4102B-L
Tektronix DPO4102B
Tektronix DPO4102
Tektronix DPO4000 Series
Tektronix DPO4000B Series
Tektronix DPO4034
Tektronix DPO4032
Tektronix DPO4054B
Tektronix Categories
Test Equipment
Measuring Instruments
Amplifier
Printer
Portable Generator
More Tektronix Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL