DESCRIPTION OF EMERGENCY INDICATIONS
When something unusual as shown below occurs in the deck, LED begins flashing for approx. 15 seconds to indicate an Emergency.
No.
Information
1
Cylinder Lock
2
Takeup-Reel Lock
Battery Under
3
Cut or DEW
NOTE :
: Indicates LED Flashing at 3Hz rate (duty 50%)
: Indicates LED Flashing at 0.8Hz rate (duty 50%)
: Indicates LED Flashing at 1Hz rate (duty 50%)
TALLY LED/
POWER LED
REC LED
1-20
Cause and Characteristic
CYLINDER Motor stops in the REC, PB, CUE,
REVIEW or STILL MODE for 2 second.
There is no TAKEUP REEL sensor pulse for 2.3
seconds (PLAY, REC) or 0.7 second (CUE, REVIEW,
FF, REW).
When the Battery voltage drops to 5.3V.
Or excessive moisture condenses in the Unit.