SERVICE MODE SPECIFICATION (SELF-DIAGNOSTIC SYSTEM)
Operation : a. Start-up : Press and hold all of the Display, REC, and Stop buttons over 2 seconds, the unit goes into the self-
diagnostic mode and main menu appears.
b. Mode Selection : Press display button to change and select self-diagnose mode.
c. Close : Turn off the Power Switch.
Display : Following descriptions can be displayed on EVF and TV monitor at the same time.
1. Main Menu
SERVICE MODE
START: DISPLAY BUTTON
QUIT : POWER OFF
2. Auto Stop
A.AUTO STOP
NORMAL
RESET: STOP BUTTON
3. Auto Test
B.AUTO TEST
SET VCR/CAMERA SW TO
CAMERA
1. CASSETTE TAPE IN
2. PRESS REC BUTTON
DISPLAY BUTTON
DISPLAY BUTTON
REC BUTTON
1-15
Press and hold all of the Display, REC and Stop buttons
over 2 seconds. The Main Menu appears on E.V.F. and TV
monitor.
When the unit suddenly shuts off, It is possible to see the
cause description in this menu. Even if the AC adaptor or
battery is disconnected, the most recent failure will be
memorized. Pressing the Stop button at this time will reset
the memory.
LOADING LOCK **
CYLINDER LOCK
TAKEUP REEL LOCK
*
SUPPLY REEL LOCK
DEW
BATTERY UNDER CUT
STANDBY MODE
* Cause descriptions can be displayed until power shuts off.
** LOADING LOCK --- EJECT
STOP
STBY
REC / PB
(When it is possible to detect the lock position, loading lock
position can be displayed.)
a. Cassette tape in and Press REC button.
b. The unit operates automatically on tests.