5.13.3 Fuel Regulators

The typical gaseous fuel system uses two regulators.
The primary regulator reduces the line pressure to an
allowable inlet pressure for the secondary regulator.
The fuel supplier provides and maintains the primary
regulator. The secondary regulator is factory-installed
on the generator set and is designed for a maximum
inlet pressure of 2.7 kPa (6 oz./in.
water column.
Note: Do not attempt to adjust the fuel mixture or engine
speed by adjusting the regulators.
The fuel lockoff prevents fuel flow when the engine is not
operating. See Figure 5-27. Do not try to adjust the fuel
pressure, fuel mixture, or engine speed using the fuel
lockoff.
Checking the Fuel Pressure
Use a gauge or manometer to check the fuel pressure at
the secondary regulator inlet.
Measure the fuel pressure with the generator set
running at rated load. Contact the fuel supplier if the
inlet pressure is not within the range shown in
Figure 5-26.
Fuel
Natural Gas
0.87--2.7 kPa (3.5--11 inches H
LPG
1.7--2.7 kPa (7--11 inches H
Figure 5-26 Fuel Pressure Requirements
1
2
1. Fuel lockoff (do not adjust)
2. Fuel inlet, 1/2 in. NPT
3. Inlet pressure check location
Figure 5-27 Fuel Regulator
TP-6881 7/15
2
) or 280 mm (11 in.)
See Figure 5-27.
Fuel Pressure Required
O)
2
3
GM71184

5.14 Fuel Conversion

The multi-fuel system allows conversion from natural
gas (NG) to LPG (or vice-versa) in the field while
maintaining emissions-standard compliance. A trained
technician or an authorized distributor/dealer can
convert the fuel system.
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Press the generator set off/reset
button to shut down the generator set. (2) Disconnect the
power to the battery charger, if equipped. (3) Remove the
battery cables, negative (--) lead first. Reconnect the negative
O)
2
(--) lead last when reconnecting the battery. Follow these
precautions to prevent the starting of the generator set by the
remote start/stop switch.
Risk of fire.
Can cause severe injury or death.
Do not smoke or permit flames or
sparks near fuels or the fuel system.
Servicing the fuel system. A flash fire can cause severe
injury or death. Do not smoke or permit flames or sparks near
the carburetor, fuel line, fuel filter, fuel pump, or other potential
sources of spilled fuels or fuel vapors. Catch fuels in an
approved container when removing the fuel line or carburetor.
WARNING
on
the
generator
Accidental starting can
Before working on the
WARNING
Section 5 Component Testing and Adjustment
set.
99