Connecting the electrical leads and harnesses
12. Connect the engine grounding strap.
13. Connect the wires and cables on the engine block
ground.
14. Connect the P6 plug to the stepper motor, leads
1A, 1B, 2A, and 2B.
15. Connect the P7 plug to the oil temperature sensor,
leads 69 and 69R.
16. Connect the P8 plug to the ignition coil and the low
oil pressure switch, leads IGN and 13.
17. Reconnect the following alternator wiring inside
the controller junction box.
diagrams in Section 7.
a. Leads 1 and 4 to the circuit breaker
Note: For 10RESV and 12RESV models,
leads 1 and 4 must thread through the
current
directions. Ensure that the leads cross
through the current transformer when
reconnecting. See Figure 6-19.
b. Quick connection leads 55 and 55F on the
20 Amp auxiliary winding circuit breaker
c. LO and neutral Leads connected to the red
insulator on the bottom of the junction box.
18. Connect the positive lead from the starter motor to
the starter solenoid.
19. Connect the fuel line at the carburetor and secure
with the fuel line pin.
20. Connect plug P2 to the controller. Position and
secure the controller with the two controller
screws.
21. Press the OFF button on the generator set
controller.
116
Section 6 Disassembly/Reassembly
See the wiring
transformer
from
opposite
DANGER
Hazardous voltage.
Will cause severe injury or death.
Disconnect all power sources before
opening the enclosure.
Connecting the battery and the battery charger.
Hazardous voltage can cause severe injury or death.
Reconnect the battery correctly, positive to positive and
negative to negative, to avoid electrical shock and damage to
the battery charger and battery(ies).
electrician install the battery(ies).
22. Reconnect the generator set engine starting
battery, negative (--) lead last.
23. Reconnect the carburetor heater (if equipped) to
the 120VAC receptacle.
1. Current transformer
Figure 6-19 Current Transformer
Have a qualified
TP-6881
1
TP-6881 7/15