Power Supply Options/电源选项/電源選項 - Advantech HPC-8208 User Manual

2u rackmount chassis for an eatx/atx serverboard with 8 hot-pluggable drive bays
Table of Contents

Advertisement

1.3
Power Supply Options/ 电源选项 / 電源選項
HPC-8208 can accommodate a 2U-high power supply. The power supply options are
listed below.
该产品支持 2U 电源。电源选项信息请参考下表。
該產品支援 2U 電源。電源選項資訊請參考下表。
Table 1.1: Power Supply Options/ 电源选项 / 電源選
550W max.
Watt
(80+ Platinum)
功率
(1+1 redundant 2U)
Input
Rating
100 ~ 240 Vac
输入电压
輸入電壓
Output
+3.3V @12A, +5V @12A
Voltage
+12V @45.8A, -12V
输出电压
@0.3A +5Vsb @5A
輸出電壓
Minimum
Load
+12 V @ 0.5 A
最小负载
最小負載
> 500,000 hours
100% Load and 55°C, as
MTBF
calculated by Telcordia
SR-332 Issues 2
Safety
CB/UL/TUV/CCC
安规认证
安規認證
Caution! Updates regarding power supply options will be published in the product
datasheet provided on the Advantech website.
请以研华公司官方网站公告的该机箱产品型录上的电源选项料号为准。
請以研華公司官方網站公告的該機箱產品型錄上的電源選項料號為準。
HPC-8208 User Manual/ 用户手册
800W max.
(80+ Platinum)
(1+1 redundant 2U)
V
100 ~ 240
ac
+3.3V @25A, +5V @25A
+12V @65A, -12V @0.3A
+5Vsb @4.5A
+12 V @ 0.5 A
>100,000 hours
100% according to Bell-
core TR-322 at 25 °C
CB/UL/TUV/CCC/KCC
4
850W max.
(80+ Platinum)
1U single Flex ATX
100-240 Vac
+3.3V @20A, +5V @20A,
+12V @70.8A, -12V
@0.5A, +5Vsb
N/A
>100,000 hours
100%, according to Tel-
cordia SR-332 at 25°C
CB/UL/TUV/CCC/KCC

Advertisement

Table of Contents
loading

Table of Contents