Engine Control

PowerCruise
II
TM
This feature allows the operator to operate the machine in an efficient mannor.
In road mode:
The engine is operated at the lowest possible speed whilst maintaining tractive
effort. Engine rpm ranges between 1200-1800rpm.
In field mode (Full load crop conditions):
Automatically adjusts the engine and ground speed in order to maintain maximum
capacity
In field mode (Partial load crop conditions):
Automatically controls engine speed to maintain optimum fuel consumption level.
In field mode (Headland operation):
During headland operation the engine rpm will be reduced to 1700rpm whilst the
header is in the raised position. When the header is lowered the engine rpm will
increase to a value depending on what ECO mode is active.
PowerCruise
II Sensitivity
TM
The PowerCruise
II sensitivity can be adjusted through the monitor. The system
TM
sensitivity may require adjustment depending on crop conditions especially and
level of variation in crop yield through a field.
NOTE: It is recommended that the forward set speed is set 1.5-2 km/h above normal
forward speed. Failure to do so may cause the system to overreact.