Troubleshooting - Yard force EM U32 Instructions Manual

Electric lawn mower
Table of Contents

Advertisement

TROUBLESHOOTING

Fault/malfunction
Cause
The mains plug is not correctly
plugged in.
The socket does not supply
any power/the fuse has blown
or the RCCB has tripped.
Motor does not start
up
The button on the safety
switch was not pushed.
The motor overload protection
has triggered, the motor is
overheated.
The selected cutting height is
too low.
Collecting bag is full to the
rim or the discharge chute is
Unsteady run
clogged.
The device emits
unusual
Blade is blocked by foreign
noises Insufficient
object.
power
Blade is dull or damaged.
Collecting bag is full to the
rim or the discharge chute is
Cuttings left on
clogged.
ground
Grass is too wet.
Remedy
Check that the mains plug is fitted
properly.
Check the power cable for damage.
Let go of the safety bar and push the
button on the safety switch before
pulling the safety bar again.
Allow the device to cool down for
15-20 minutes.
Set the cutting height 2 levels
higher.
Empty the collecting bag and
remove cuttings from the
discharge chute.
Check the blade
compartment for foreign
objects and remove these if
present.
Check the blade and have it
sharpened or replaced at a
specialist workshop, if
necessary.
Empty the collecting bag and
remove cuttings from the
discharge chute.
Wait for the grass to dry.
20
DECLARATION OF CONFORMITY
To the provisions of Council Directives
MEROTEC GmbH
Otto-Brenner-Str. 8, 47877 Willich, Germany
Declare that the product:
Machine Description: Electric lawnmower
EM U32/ SLM32F
Function: Cutting grass
Complies with the essential health and safety requirements of the following directives:
Machinery Directive 2006/42/EC
Electromagnetic Compatibility Directive 2014/30/EU
EC Directive 2011/65/EU and its amendment Directive (EU) 2015/863 (RoHS)
Noise Emission in the Environment by Equipment for Use Outdoors Directive
2000/14/EC amended by 2005/88/EC
We additionally confirm the following in accordance with the 2000/14/EC amended by 2005/88/EC emis-
sions guideline,
Measured Sound Power Level: 91.14 dB(A), K=1.55 dB(A)
Declared Guaranteed Sound Power Level: 96 dB (A)
Standards and technical specification referred to :
EN 60335-1:2012+A11+A13+A1+A14+A2
EN 60335-2-77:2010
EN 62233:2008
EN IEC 55014-1:2021
EN IEC 55014-2:2021
EN IEC 61000-3-2:2019+A1:2021
EN 61000-3-3:2013+A1:2019+A2:2021
EN 50581:2012
Authorized Signatory
Date:
09.01.2023
Signature:________________________
Place: Willich
Name: Roland Menken
General Manager
MEROTEC GmbH