Cabinet Installation

1 . Drive a wood screw into the wall within
eye level until only 1/4" (10mm) of the
screw is exposed.
N O T E : If installing the controller on
drywall or masonry, install the appro-
priate type screw anchors.
2 . Hang the cabinet on the screw using
the keyhole slot.
3 . Open the controller cabinet and swing
open the timing mechanism to access
the lower mounting screw location.
4 . Install the lower mounting screw in the
hole provided and tighten securely.
5. Fill out the provided Watering Schedule form with program and system details.
A ffix the provided velcro disks to the form in the designated locations. Attach the
form to the inside of the cabinet cover.

Field Wire Connections

NOTE: Using 14–18 AWG (2–1mm
field wire connections is recommended. This cable is made specifically for
underground installation and is available in various lengths and conductor count.
Select a cable that has at least one conductor for each valve connection and
one conductor to provide a valve common connection.
1. Route the valve control wires between the valves and the controller.
2. Attach the white wire to either lead from each valve solenoid to provide a
valve common wire.
3. Attach a separate wire to the remaining valve solenoid lead of each valve.
NOTE: For reference when making wire connections at the controller, note of
the wire color used for each control valve connection and the corresponding
watering zones.
4. Secure all wire splices using water-proof wire connectors or any appropriate
method of protecting wire splices from direct contact with soil or moisture.
5. Route the cable into the controller through one of the 3/4" (19mm) access
holes in the base of the housing or through the PVC conduit (if installed).
Strip insulation back 3/8" (10mm) for wiring terminal connections.
6. Secure the field common wire(s) to common terminal(s) (C).
7. Secure the individual valve wires to the appropriate expansion module
station output terminals
8. Connect one wire from the master valve or pump start relay to terminal (P).
22
5:00 PM
Page 22
2
) multi-strand irrigation hookup cable for
7"
(17,78mm)