NOTE: A program must have the MV/PS control option enabled to permit
individual stations assigned to the program to be excluded from MV/PS opera-
tion. In other words, assigning MV/PS operation by station is not applicable
unless MV/PS operation for its assigned program is enabled.
• Master Valve/Pump Start Operation by Program
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
3. Press the
4. To exclude the selected program from MV/PS operation, press the
button to select MV[A] – N (Master Valve [program A] – No).
• Master Valve/Pump Start Operation by Station
1. Press the
2. To access this option, the option must first be enabled by pressing the
or
be solid circles (all enabled).
3. Press the
The station identifier will begin flashing.
4. Press the
skip the station. When excluded, the station identifier will change from solid
to hollow. The next station identifier in sequence will begin flashing.
5. Repeat the procedure in step 4 as needed for each station.
• To Set Pump Delay
This feature enables a delay period from 1 to 60 seconds to occur after the MS/PS
circuit is activated, and prior to the start of the first station in the watering sequence.
This delay feature is often used in conjunction with the Station Delay (SD) feature.
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
3. Press the
4 . Press the
• To Set Pump Enable
This feature allows you to enable or disable MV/PS operation for the duration of a
Station Delay period.
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
3. Press the
4. Press the
5:00 PM
Page 11
button to display M VA -- Y (Master Valve [program A] - Yes [on]).
button to display MVS -- N (Master Valve Stations – No).
button to select MVS -- Y (Yes). By default, all station identifiers will
button to select MV -- Y 01 (Master Valve--Yes, station 01).
button to exclude selected station, or press the
button (as needed) to display PD -- -- (Pump Delay Off).
o r
button to select the delay time value from 01 to 60 seconds.
button as needed to display PE - - N (Pump Enable - No [Off]).
or
button to select PE - - Y (Pump Enable - Yes [On]).
.
button to
.
.
or
11