Back Module; Back Module Components; Back Module Installation - Toro TEMPUS 53828 User Manual

Table of Contents

Advertisement

Available languages

Available languages

BACK MODULE

Back Module Components

1. Terminal board.
2. DB15 Connector to the programming module.
3. Conduit knockout.
4. Mounting holes for wall installation.
5. Mounting holes for electrical wall box installation or for alternative
wall installation.
6. Jumper to be connected to the SENSOR terminals if no rain sensor is used.
2
5
6
3
4
1
4
3
5

Back Module Installation

1. For safe, reliable operation, select an installation site which can ideally provide
the following conditions:
• Inside a garage or other structure which will provide protection from the
weather.
• Access to a grounded AC power source (within 4 ft.) which is not controlled by a
light switch or utilized by a high current load appliance, such as a refrigerator
or air conditioner.
• Access to the sprinkler control valve wiring and optional accessory wiring.
2. Position the back module on the wall at eye level and drive the first wood screw
through the top opening (A). Position the back module horizontally and drive the
second wood screw through the opening (B). See Figure 1.
Note: If installing the controller on drywall or masonry, install screw anchors.
Install the lower screw anchor 2.9 in. directly below the top screw anchor.
Note: Conduit and adapters are not provided. Install conduit as required by local
electrical codes.
6. Remove the conduit knockout. Install 0.5 in. conduit (C) and (D) for 24 VAC power
wires and for valve wires.
Toro TEMPUS Controller
5

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Tempus 53829Tempus 53827

Table of Contents