If your air conditioner is not fitted with a supply cord and a plug, an
anti-explosion all-pole switch must be installed in the fixed wiring and
the distance between contacts should be no less than 3.0 mm.
If your air conditioner is permanently connected to the fixed wiring, a
anti-explosion residual current device (RCD) having rated residual
operating current not exceeding 30 mA should be installed in the
fixed wiring.
The power supply circuit should have leakage protector and air
switch of which the capacity should be more than1.5 times of the
maximum current.
Regarding the installation of the air conditioners, please refer to the
below paragraphs in this manual.

Notices for use

The conditions of unit can't normally run
Within the temperature range provided in following table, the air conditioner may
stop running and other anomalies may arise.
Cool
Heat
* When the temperature is too high, the air conditioner may activate the
automatic protection device, so that the air conditioner could be shut down.
* When the temperature is too low, the heat exchanger of the air conditioner may
freeze, leading to water dripping or other malfunction.
* In long-term cooling or dehumidification with a relative humidity of above 80%
(doors and windows are open), there may be water condenses or dripping
near the air outlet.
* T1 and T3 refer to ISO 5151.
>43 ºC (Applicable for T1)
Outside
>52 ºC (Applicable for T3)
Inside
<18 ºC
>24 ºC
Outside
<-7 ºC
Inside
>27 ºC
9
-