Installation; Sensor Orientation - Banner Q4X Quick Start Manual

Stainless steel laser sensor
Hide thumbs Also See for Q4X:
Table of Contents

Advertisement

Q4X Stainless Steel Laser Sensor

Installation

Install the Safety Label
The safety label must be installed on Q4X sensors that are used in the United
States.
Note: Position the label on the cable in a location that has
minimal chemical exposure.
1. Remove the protective cover from the adhesive on the label.
2. Wrap the label around the Q4X cable, as shown.
3. Press the two halves of the label together.

Sensor Orientation

Optimize detection reliability and minimum object separation performance with correct sensor-to-target orientation. To ensure
reliable detection, orient the sensor as shown in relation to the target to be detected.
See the following figures for examples of correct and incorrect sensor-to-target orientation as certain placements may pose
problems for sensing some targets. The Q4X can be used in the less preferred orientation and provide reliable detection
performance; refer to the Performance Curves for the minimum object separation distance required for each case.
Figure 7. Orientation by a wall
Correct
Incorrect
Figure 10. Orientation for a color or luster difference
(Optimal)
Horizontal
Orientation
Orientation
Mount the Device
1. If a bracket is needed, mount the device onto the bracket.
2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the
mounting screws at this time.
3. Check the device alignment.
4. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.
1
Applying tilt to sensor may improve performance on reflective targets. The direction and magnitude of the tilt depends on the application, but a 15° tilt is often sufficient.
P/N 181484 Rev. N
Figure 6. Optimal Orientation of Target to Sensor
Figure 8. Orientation for a turning object
Correct
Figure 11. Orientation for highly reflective target
Vertical
www.bannerengineering.com - Tel: + 1 888 373 6767
Incorrect
1
Reflective
Surface
(optional)
Figure 5. Safety Label Installation
COMPLIES WITH 21 CFR 1040.10 AND 1040.11
EXCEPT FOR DEVIATIONS PURSUANT TO
CLASS 1
LASER NOTICE No. 50, DATED JUNE 24, 2007.
LASER PRODUCT
BANNER ENGINEERING CORP.
9714 10TH AVENUE NORTH
COMPLIES WITH IEC 60825-1:2007
MINNEAPOLIS, MN 55441
Figure 9. Orientation for a height difference
Correct
Incorrect
3