Page 1
THERMAL WIRE STRIPPER FT-802 Instruction Manual Thank you for purchasing the HAKKO FT-802 Thermal Wire Stripper. Be sure to read this manual before operating the HAKKO FT-802. Keep this manual readily accessible for reference.
Plug Power receptacle Wire material Hexagon wrench indicator seal Power cord PACKING LIST HAKKO FT-802 station ........1 Hexagon wrench (1.27mm) ......1 HAKKO FT-8004..........1 Instruction Manual ..........1 Power cord .............1 Hexagon socket set screw (M2.5x2.5) ...2 Wire material indicator seal ......1 2.
Do not modify the HAKKO FT-802. Do not allow the HAKKO FT-802 to become wet, or use it when hands are wet. Since smoke is produced when using the wire stripper, be sure the work area is well ventilated.
4. INITIAL SETUP 4-1 Blades 4-1-1 Attaching blades ① Stop provisionally in the tapped hole of the V groove handle, and do a set the hexagon socket set screw. ② Insert the blade so that the blade mounting fl ange locks into the FT-8004.Merge type V and the V-groove of the back of the blade.
4. INITIAL SETUP (continued) 4-2 Station ① Connect the power cord to the inlet on the rear side of the station. ② Place the HAKKO FT-8004 on the handle holder with the blades facing up. ③ Plug the handle plug into the receptacle. ④...
NOTE: The output value range is 5% to 100%.The output values can be set in increments of 5%. If the output is 80% or less, will be displayed when the handpiece is placed on the station indicating the timer start for the auto sleep setting set by parameter 02. If , or "Enter" are pressed while ...
5. HOW TO USE (continued) 5-3-2 How to use the lead adjuster The lead adjuster is a tool for setting the wire stripping length. Adjuster plate Adjust the distance between the blade end and the adjuster plate to the desired wire stripping length and slide it.
6. SETTING PARAMETERS To make this product more convenient to use, the HAKKO FT-802 has the following parameters which can be set. The parameter settings can be changed to suit your use environment. • Password setting • Auto sleep enable/disable setting Setting a password allows you to lock the settings The auto sleep function can be enabled or disabled.
6. SETTING PARAMETERS (continued) 6-2 Parameter setting procedure Parameter input mode flowchart Follow the steps below to input parameter values. ①Hold the buttons pressed while switching on the power to enter parameter input mode. ②Select the parameter number. Initially, the parameter number will be blinking.
Page 11
Password setting Setting a password enables the set output value or parameter values to be locked. The password is set by selecting a combination of 3 characters from among the 6 characters of The password setting has 3 levels. : Disabled (no lock) : Partially enabled.
Page 12
WARNING The high temperature at 105% - 120% could shorten blade life or that the blade will glow red. Place the handle on the handle holder when not using the HAKKO FT-802. High output setting Enable or disable the high-output function.
Page 13
Auto sleep time setting This function operates when the Auto sleep enable/disable setting is set to (enabled). Set the time until the auto sleep function operates after placing the handle on the handle holder. When the time is set , the auto sleep function starts immediately after placing the handle on the handle holder. Display: is lit.
7. MAINTENANCE The unit should be maintained periodically to be able to use it in proper condition for a long time. Since the degree of consumption of the unit varies depending on the use temperature, etc., perform maintenance of the unit according to use conditions. WARNING Since the soldering iron can reach a very high temperature, please work carefully.
9. TROUBLESHOOTING WARNING Be sure to unplug the power cord before repairing. Failure to do so may cause an electric shock. Phenomenon Check Actions The unit does not work Is the power cord or the connection Connect the power cord and connection even when the power is plug disconnected? cord.
Page 16
Part name Specifications B5244 Blade removal plate w/screw B5245 Handle holder w/SEMS screw M3×18 Qty 2 for HAKKO FT-802 B2387 Power cord/3 core & American plug B2419 Power cord/3 core & American plug B2421 Power cord/3 cored wire with no plug B2422 Power cord/3 core &...