Hakko Electronics FR-810 Instruction Manual
Hide thumbs Also See for FR-810:

Advertisement

Instruction Manual
Thank you for purchasing the HAKKO FR-810 SMD Rework Station.
This unit features:
● Digital control and display of time and temperature
● Digital control and display of air-flow rate
● Preset feature for programming temperature, time, and airflow settings
Please read this manual before operating the HAKKO FR-810.
Keep this manual readily accessible for reference.
1. PACKING LIST AND PART NAMES
HAKKO FR-810 station
Handpiece holder
FP pick-up {with FP pick-up wire(SS)}
Heat resistant pad
Handpiece

2. SPECIFICATIONS

Power consumption
100V-700W 110V-840W 120V-820W
220V-1100W 230V-1200W 240V-1300W
● Handpiece
Power consumption
100V-670W 110V-810W 120V-790W
220V-1070W 230V-1170W 240V-1270W
250 mm (9.8 in.)
Total length (w/o cord)
180 g (0.40 lb.)
Weight (w/o cord)
* This product is protected against electrostatic discharge.
* Specifications and design are subject to change without
notice.
CAUTION
This product includes such features as electrically
conductive plastic parts and grounding of the
handpiece and station as measures to protect the
device to be soldered from the effects of static
electricity. Be sure to observe the following
instructions:
1. The handle and other plastic parts are not
insulators, they are conductors. When replacing
parts or repairing, take sufficient care not to
expose live electrical parts or damage
insulation materials.
2. Be sure to ground the unit during use.
SMD Rework Station
Please check to make sure that all items
listed below are included in the package.
Power cord
1
Instruction manual
1
1
1
handpiece holder
attachment plate
Handpiece holder
HAKKO FR-810
station
Heat resistant pad
Temp/Time indicator
Air indicator
● Station
Power consumption
Capacity (Airflow)
Control temperature
Outer dimensions
Weight
* Airflow capacity is rated as free flowing. Restrictions
created by various nozzles may reduce the maximum
airflow capacity.
電路板
水平支架
連接器
插座
1
1
Power cord
FP pick-up
FP pick-up wire(SS)
30 W
1 - 9 (5 - 115L/min*)
50 - 600℃ (120 - 1120℉)
160(W) × 145(H) × 220(D) mm
(6.3 × 5.7 × 8.7 in.)
1.5 kg (3.3 lb.)

Advertisement

Table of Contents
loading

Summary of Contents for Hakko Electronics FR-810

  • Page 1: Specifications

    SMD Rework Station Instruction Manual Thank you for purchasing the HAKKO FR-810 SMD Rework Station. This unit features: ● Digital control and display of time and temperature ● Digital control and display of air-flow rate ● Preset feature for programming temperature, time, and airflow settings Please read this manual before operating the HAKKO FR-810.
  • Page 2: Warnings, Cautions, And Notes

    ● Do not modify the unit. ● Use only genuine HAKKO replacement parts. ● Do not allow the HAKKO FR-810 to become wet, or use it when hands are wet. ● Remove the power cord by holding the plug - not the cord.
  • Page 3: Operation

    4. INITIAL SETUP C. Electrical connection and power ON 1. Insert the power cord into the receptacle on the rear panel of the station. 2. Place the handpiece on the holder. The rim of the handpiece must rest on the area circled in the illustration.
  • Page 4 (When not using the timer function, select “---”. When set in the timer setting “000” , don't work. ) ● Preset mode In addition to the procedure described remove above, HAKKO FR-810 includes a preset mode allowing the selection of temperature, time, and airflow from the options you define (up to 5 temperature/time/airflow settings can be programmed).
  • Page 5: Parameter Setting

    Pressing the button once allows you to check the settings of the set temperature and set time in this order. 6. PARAMETER SETTING The HAKKO FR-810 has the following parameters: Parameter name Parameter No. Value Initial value ℃ / ℉ selection ℉...
  • Page 6 6. PARAMETER SETTING ●   :℃ or ℉ temperature display seletion The displayed temperature can be switched between Celsius and Fahrenheit. ●   :Auto sleep ON/OFF setting Select whether you will activate the auto sleep function. ●   :Auto shutoff ON/OFF setting Select whether you will activate the auto shut off function. ●   :Setting mode selection Temperature setting can be switched between the normal mode and the preset mode.
  • Page 7 6. PARAMETER SETTING E. Password setting 1. Either will be displayed if you press the button when is displayed. 2. If you press the ) button, (Open), (Partial) and (Restricted) will be switched alternately. 3. If you press the button after selecting, the display will return to .
  • Page 8: Temperature Distribution Chart

    ● These charts do not define the temperature characteristics, and are for reference only. ● The temperature distribution charts for HAKKO 850 or 850B should not be used for FR-810. FR-810 uses a different pump and control system. When you use the FR-810, make sure to refer to the temperature distribution charts shown to the under.
  • Page 9 7. TEMPERATURE DISTRIBUTION CHART N51-03 Single ø5.5 (0.22) ℃ (1292℉) ℃ (1112℉) ⑥ ℃ (932℉) ⑤ ℃ (752℉) ④ ℃ (572℉) ③ ℃ ② ①100℃ (392℉) ②200℃ ③300℃ ℃ ① ④400℃ (212℉) ⑤500℃ ⑥600℃ ℃ (32℉) N51-04 Single ø7.0 (0.28) ℃...
  • Page 10: Maintenance / Inspection

    Handle the heating element with care. Never touch the heating element wire! 9. TROUBLE SHOOTING GUIDE   WARNING Before checking the inside of the HAKKO FR-810 or replacing parts, be sure to disconnect the power plug. Failure to do so may result in electric shock. CHECK:...
  • Page 11: Parts List

    10. PARTS LIST ⑤ ① Insulation ring ⑦ Heat insulation fiber ④ ⑩ ③ ⑨ ② ⑧ ⑪ ⑥ ● HAKKO FR-810 Item No. Part No. Part Name Specifications A5005 Heating element 100-110V ① A5006 120.127V Heating element A5007 Heating element...
  • Page 12 10. PARTS LIST ● Optional parts Item No. Part No. Part Name Specifications B5056 FP pick-up ① With pick-up wire (SS) B5057 FP pick-up wire (SS) ② B2300 Heat resistant pad ③ B5059 adapter ×2 ④ 11. OPTIONAL PARTS (Nozzle) Unit: mm (in.) N51-01 Single ø2.5 (0.1)

Table of Contents