Installation of Refrigeration Piping from Vertical to Horizontal
Outside Wall
Fiberglass Insulation
I
MPORTANT:
Refrigerant lines must NOT
come into contact with structure.
NOTE: If line set is installed on the exterior of an outside wall, similar installation practices are to be used.
Hanger
Wall
Stud
Metal
Sleeve
Figure 1-1
IMPORTANT - Refrigerant lines must not touch wall.
Outside Wall
Wood Block
Between Studs
Armaflex
®
Wrapped
Suction Line
Liquid
Line
Caulk
PVC Pipe
Figure 1-2
Installation of Refrigeration Piping (Vertical)
New Construction Shown
11
Liquid Line
Strapped to
Suction Line
Liquid Line
Suction Line
Wrapped in Armaflex
®
Suction Line
Wire Tie
Inside Wall
Strap
Sleeve
Wood
Wire Tie
Block
Strap
Sleeve
Liquid Line

Advertisement