Other Faults - Kaco blueplanet hybrid 10.0 TL3 Manual

Hide thumbs Also See for blueplanet hybrid 10.0 TL3:
Table of Contents

Advertisement

I906
Power reduction
overfrequency
I907
Power reduction
underfrequency
I908
Unsaved settings
I909
AC overvoltage
I910
Software
I911
hy-switch connection
I912
Power reduction
overvoltage
9.4

Other faults

Fault pattern:
Display without function and device cannot be switched on
Possible solutions:
– The device runs without battery power and is shut down at night. It starts
automatically the next day.
– The device runs without battery power and the power supply from the PV modules is interrupted. Check the
position of the DC isolating switch and the fuse protection of the
supply line. Contact your installer.
– The device has a power supply fault. Check the power supply and functioning of the battery. Contact your
installer.
Page 58
Power reduction due to overfrequency. Wait until the result is
no longer present.
Power reference due to underfrequency. Wait until the result
is no longer present.
New settings have been made on the device, but have not yet
been saved. If necessary, the settings can be saved under User
Settings.
AC overvoltage detected. Wait until the result is no longer
present. If it persists, check the installation.
Incompatible software versions. Update software
Unstable connection to hy-switch. Check the installation.
Power reduction due to overvoltage. Wait until the result is
no longer present.