5.1 Basic Operation

Basic Operation
When the door receives activation, the door opens and brakes before the fully open position and opens slowly to the
full doorstop position, following the programmed data.
Once pre-set open period is complete, the door will close at the pre-set closing speed, braking to low speed a little
before the fully closed position and closes slowly.
When an activation signal activates while the door is closing, the door will stop and reverse to open.

5.2 Operation Switch

Operation (3 position) Switch is located on the end plate.
With the door in the closed position. Check that the door is unlocked and the main power switch is on.
Automatic Mode (I)
This mode sets to activate the operator
Activate the push button or knowing act device. The door opens to about 80 degree position at full speed, and then
will slow for the final 10 degree of opening until full open is complete. (There is no need for a learning cycle as the
open position is already pre-set during installation).
After the pre-set open time is complete, the door will begin to close at the set closing speed, until the final 10 degree of
closing, when the door will slow for the final 10 degree of closing until the full latch position.
Hold Open Mode (II)
This mode sets to hold the door open automatically for an extended length of time.
No activation or safety sensor signals will be active in this mode as the door is stationary in the open position. The door
will remain held open continually by a pulsed signal to the motor without overheating.
To close the door, move the switch to either Automatic (I) or OFF (0) position, and the door will close smoothly and
gently to the full closed position.
OFF (Manual) Mode (O)
This mode sets to deactivate all opening signals, and the door is opening and closing manually.
No activation signals or safety sensor signals (if equipped) will be active in this mode as the door is stationary in the
closed position.
Power will remain ON and supplied to the unit, however all signals will be ignored. The door can be opened easily with
minimum force.
Record Canada Inc.
Toll Free: 1-877-348-6837
info.ditec.ca@recorddoors.com
www.recorddoors.ca

5.0 DOOR OPERATING MODE

The Operation Switch must be set to Automatic (|)
position to allow changes to be made in programming.
Record USA Inc.
Toll Free: 1-866-901-4284
info.ditec.us@recorddoors.com
www.recorddoors.com
HOLD OPEN
OFF
AUTOMATIC
HA8-SP Manual V. 7.0
Pg. 44