Pneumatic Cylinder Operation - Conair CTS 5 User Manual

Traveling saw
Table of Contents

Advertisement

P
NEUMATIC
C
YLINDER
O
PERATION
4-6
O
PERATION
The carriage travel, blade pivot and clamp assemblies are
moved with air cylinders. The speed of the movement of the
carriage assembly is controlled by flow controls located on
the operator panel. Clockwise rotation will slow the table
speed and counterclockwise rotation will increase the table
speed.
The blade pivot assembly is moved up and down with an air
cylinder located below the table. It is controlled by flow con-
trols mounted on the operator panel. These are labeled table
up speed and table down speed. Clockwise rotation will slow
the table movement speed and counterclockwise rotation will
increase the table movement speed.
The clamp assembly is moved up and down by air cylinders
mounted above the clamp. They are controlled by flow con-
trols mounted on the Cylinders. Clockwise rotation will slow
the clamp movement speed and counterclockwise rotation will
increase the clamp movement speed.
The table and clamp pressure setting is adjusted with a pres-
sure regulator located on the operator panel. The pressure
level setting is displayed on the gauge located above the regu-
lator. The table and clamp pressure should never exceed 60
PSI.
The main filter/regulator/lubricator is mounted on the side of
the machine near the electrical enclosure and should be main-
tained as described in the manufacturers documentation.
This unit should always be supplied with clean dry air.
Incoming pressure should be set at approximately 65 PSI.
Maximum pressure is 70 PSI.
IMPORTANT: This unit should always be supplied with
clean dry air. Incoming pressure should be set at
approximately 65 PSI. Maximum pressure is 70 PSI.