Manual Stick Set-Up Mode
1
2
4
1 Set-Up Button
2 Left Knob
3 Right Knob
4 Home Button
To enter the Setup menu from the Manual
Mode home screen, press Setup.
Once in the Setup menu, rotate the left knob
to find a particular item, and rotate the right
knob to change setting or status.
�
Complete Parts List is available at www.MillerWelds.com
Press Home to save settings and return to
welding mode.
Items that can be adjusted from this menu
are:
DIG: Controls the amount of additional am-
perage at low voltage conditions. Dig set-
tings range from 0 to 99. Pro-Set references
the default setting. Default setting varies
with electrode type.
Hot Start: Provides more amperage at the
start to ignite the arc and reduce electrode
sticking. Hot start settings range from
277656-C
Disabled to 300%. The default hot start set-
ting is 100%.
Adaptive Hot Start: : Enabling Adaptive
Hot Start optimizes the re-ignition of the
electrode when doing repetitive arc starts.
Adaptive Hot Start automatically uses a larg-
er hot start current when the electrode is
cool and a smaller hot start current when the
electrode is hot. The default setting is
disabled.