Download Print this page

Rs232 Communication Port; Dip Switch Settings - Leadshine Technology 3DM2283 User Manual

3-phase digital stepper drive

Advertisement

response, DIR signal should be ahead of PUL signal by 5μs at least. 4-5V when DIR-HIGH,
0-0.5V when DIR-LOW. Please note that rotation direction is also related to motor-driver
4
DIR-
I
wiring match. Exchanging the connection of two wires for a coil to the driver will reverse
motion direction. The direction signal's polarity is software configurable.
Enable signal: This signal is used for enabling/disabling the drive. In default, high level
5
ENA+
I
(NPN control signal) for enabling the driver and low level for disabling the driver. Usually
left UNCONNECTED (ENABLED). Please note that PNP and Differential control signals
are on the contrary, namely Low level for enabling. The active level of ENA signal is
ENA-
6
I
software configurable.
Fault Signal: OC output signal, active when one of the following protection is activated:
7
FAULT+ O
over-voltage, over current, low voltage, phase error and over-temperature. This port can
sink or source 20mA current at 24V. In default, the resistance between FAULT+ and
FAULT- is high impedance in normal operation and become low when 3DM2283 goes into
8
FAULT- O
error.

RS232 Communication Port

The RS232 communication port is used to configure the 3DM2283's peak current, microstep, active level, current loop parameters and
anti-resonance parameters. See DM driver's software operational manual for more information.
RS232 Communication Port
Name
I/O
Pin
NC
-
1
+5V
O
2
TxD
O
3
GND
GND
4
RxD
I
5
NC
-
6

DIP Switch Settings

Dynamic Current
Peak
RMS
Default
Default
2.2A
3.1A
4.5A
3.2A
5.9A
4.2A
7.3A
5.2A
8.9A
6.3A
10.1A
7.2A
8.3A
11.7A
Description
Not connected.
Not connected.
RS232 transmit.
Ground.
RS232 receive.
Not connected.
SW1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Page 5 of 7
High Voltage Digital Stepper Drive 3DM2283 Manual
SW2
SW3
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON

Advertisement