Siemens SICHARGE UC Installation And Commissioning Manual page 26

Hide thumbs Also See for SICHARGE UC:
Table of Contents

Advertisement

Functional verification
No.
1
After the DC shutdown button was pressed, the HMI shows the emergency button pressed screen.
2
After the DC shutdown button was released, the HMI goes to the normal state.
3
After the charger door open, the HMI shows the screen advising the door is open.
4
After door closed, the HMI goes to the normal state.
5
In case of a system with dispenser, after the dispenser door open, the HMI shows the screen advis-
ing the door is open.
6
After door closed, the HMI goes to the normal state.
7
In case of a system with dispensers, the communication between dispenser and charger was veri-
fied.
8
The communication via OCPP was verified.
9
The communication via Modbus was verified.
10
The display backlight was verified.
11
The touchscreen was verified.
12
The menu option is working.
13
Charger door is locked.
14
Dispenser door is locked.
Checking the charging session
No.
1
As soon as CCS plug was connected to the vehicle inlet, the charging process started.
2
HMI shows "Charging in process" (please, wait 60 seconds)
3
Current ramps up to meet the demand of the vehicle.
4
End the session using the dedicated stop button on the HMI.
5
Charging process stops
6
Charge finished is displayed on the HMI.
7
Download the session log from the configuration webserver.
8
Write down the vehicle model used for testing.
9
Remove the plug and wait 10s.
10
Reconnect the vehicle.
11
Repeat the steps from 1 to 6.
12
Charging process stops with success
Finalizing Commissioning Operations
No.
1
All the applicable steps were done with success and marked as passed.
2
All data about the charger was filled in.
3
All data about the customer was filled in.
4
All data about the commissioning responsible was filled in.
5
The commissioning log report was signed by the commissioning responsible person.
Installation and Commissioning Checklist for SICHARGE UC
Product Information, 03/2023, A5E52548271-AA
Checklist item
Checklist item
Checklist item
SICHARGE UC Charger
3.5 Commissioning
P
F
N/A
P
F
N/A
P
F
N/A
25