Installation; Technical Specifications - Videotec VIP6A1 Operating Instructions Manual

Heg wiper
Table of Contents

Advertisement

Camera housing and accessories
DESCRIPTION
Wiper device for cleaning the camera housing
glass window. For outdoor electrical connections
the appliance is fitted with a 3+PE round connector.
Tu r n
o f f
p e r f o r m i n g
operations.

INSTALLATION

Installing the wiper kit on the
housing.
1. Remove the front flange on the housing by
unscrewing the three front screws (Fig.1).
2. Insert the wiper body by slotting the slide onto
the profile of the housing body (Fig.2).
3. Slide the wiper body along the housing body
(Fig.3).
4. Re-assemble the front flange on the housing by
tightening the three front screws (Fig.4), making
sure the sealing gasket is seated properly.
5. Assemble the wiper blade on the output shaft,
fixing it in the rest position on the left side of
the glass front (Fig.5).
6. Lock the wiper body by tightening up the

TECHNICAL SPECIFICATIONS

-Materials:
PP Technopolymer
Painted steel (blade)
-Gaskets:
Neoprene ®
Viton ®
-Flammability rating: Conformity with UL-94 V0
-Colour:
RAL 9002
-External dimensions: 99 x 215 x 209 mm / 3.9 x 8.5 x 8.2 in
t h e
p o w e r
b e f o r e
a n y
k i n d
dowels on the fixing slide so that the blade
exerts the correct pressure on the housing
glass (Fig.6).
WIRING
M a k e s u r e t h e p o w e r s u p p l y
o f
voltage used is the same shown
on the plate on the back of the
appliance.
Make the electrical connections on the female
3+PE connector as shown in the electrical
diagram (Fig.7):
1. Power the wiper by connecting the phase to
terminal 3 (SW) on the connector and neutral
to terminal 2 (COM) on the connector.
2. Use an external button to connect the phase to
terminal 1 (PERM) on the connector.
3. Keeping the external button pressed will cause
continuous operation (permanent) of the
wiper. Releasing the button will take the wiper
blade to the rest position on the left side of the
housing window.
4. If a receiver is used, connect terminal 3 of the
connector to the SW output on the receiver, 1
to PERM and 2 to COM.
-Weight:
-Power supply:
-Wiring:
-Protection rating:
-Working temperature:From –20°C to +50°C / from –4°F to +122°F
2
0.7 kg / 1.5 lb
230 VAC 50/60 Hz, 7 W
24 VAC 50/60 Hz, 7 W
Wires 0.5 ÷1.5 mm2
Ø est cable 6÷12 mm
IP67
ENGLISH