Page 1
MANUAL COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us concerning this unit, it will help us to respond to your needs faster.
Should you experience a problem please follow the “Troubleshooting Tables” near the end of this manual. The warranty listed in the manual describes what you can expect from WINCO should you need service assistance in the future. 60706-220/E...
SAFETY IMPORTANT SAFETY INSTRUCTIONS D. Keep a fire extinguisher nearby and know its proper use. Fire extinguishers rated ABC by NFPA are SAVE THESE INSTRUCTIONS appropriate. E. Store fuel only in an approved container, and only in This manual contains important information that should be a well ventilated area.
This portable unit requires large quantities of fresh air for cooling the engine and generator. For safety, long life and adequate performance, these units should never be run in W3000H/D small compartments without positive fresh air flow. Starting Watts 3,000...
UNIT CAPABILITIES GENERATOR CONNECTIONS CAUTION: EQUIPMENT DAMAGE Running the generator set under these conditions may 120 volt receptacles are provided for connection to various result in damage to the generator stator as well as the loads. The following diagram represents this 2,400 watt motor winding.
If any damage is noted, it is always easiest to problems. Always insure that the fuel is clean and free of all refuse the shipment and let WINCO take care of the impurities. freight claim. If you sign for the unit, the transfer of the...
INITIAL START UP The throttle control on these generators is preset and STARTING HINTS locked to operate at 3600 RPM (nominal) with no load speed set at 3690 RPM. Only a trained service technician 1. COLD WEATHER should be allowed to adjust this speed setting. A.
Page 8
described in this manual are approximately as follows, under varying loads: LOAD vs. OUTPUT Generator Speed Frequency Voltage Load (RPM) (Hz) None 3690 61.5 120V Half 3600 60.0 120V Full 3510 58.5 120V The speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency.
STANDARD PORTABLE GENERATOR near vents or windows, or anywhere carbon monoxide gas could accumulate. Your WINCO portable generator ships with a bonded neutral. You can safely use this generator without external Failure to properly limit and balance the load applied to...
They may cause Outdoor temperatures determine the proper oil viscosity for deterioration of the cartridge. the engines. Winco recommends our 5W-30 fully synthetic oil to give you excellent protection in cold temperatures while maintaining excellent performance in warmer weather.
EXERCISING THE GENERATOR cooling fins and fly wheel. Clean more often if necessary. Failure to keep these areas clean may cause overheating and permanent damage to the unit. The generator should be operated every three to four weeks. It should be operated for a period of time sufficient 2.
WINCO written instructions and applicable codes. WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service will be repaired or replaced.
Need help?
Do you have a question about the W3000H/D and is the answer not in the manual?
Questions and answers