Download Print this page

Mitsubishi CL1Y2-T1D2S Manual

Cc-link/lt remote i/o module

Advertisement

Quick Links

Side
B
Side
Side
A
B
JAPANESE
ENGLISH
CL1Y2-T1D2S
CC-Link/LT Remote I/O Module
Please read this manual thoroughly before starting to use the product and
handle the product properly.
User's Manual
MODEL
CL1Y2-T1D2S
MANUAL Number
JY997D04001C
Date
DECEMBER 2003
G G G G SAFETY PRECAUTIONSG G G G
(Read these precautions before using)
Please read this manual carefully and pay special attention to safely in order
to handle this product properly. Also pay careful attention to safely and handle
the module properly.
These precautions apply only to Mitsubishi equipment. Refer to the user's
manual of the CPU module to use for a description of the PLC system safety
precautions.
These GSAFETY PRECAUTIONSG classify the safety precautions into two
categories: "DANGER" and "CAUTION".
Procedures which may lead to a dangerous condition
and cause death or serious injury if not carried out
DANGER
properly.
Procedures which may lead to a dangerous condition
and cause superficial to medium injury, or physical
CAUTION
damage only, if not carried out properly.
CAUTION
Depending on circumstances, procedures indicated by
may also be linked to serious results.
In any case, it is important to follow the directions for usage.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
[DESIGN PRECAUTIONS]
DANGER
• Configure an interlock circuit in a sequence program so that the system
operates on the safety side using the communication status information
in the event the data link falls into a communication problem.
Otherwise, erroneous output and malfunction may result in accidents.
• Remote input and output can not be switched ON or OFF when a
problem occurs in the remote I/O modules. Therefore build an external
monitoring circuit that will monitor any input signals that could cause a
serious accident.
CAUTION
• Do not have control cables and connection cables bundled with or
placed near by the main circuit and/or power cables. Wire those cables
at least 100mm(3.94 inch) away from the main circuit and/or power
cables. It may cause malfunction due to noise interference.
• Use the module in the status in which any force is not applied on the
module, flat cables dedicated to CC-Link/LT and flat cables for I/O.
If a force is applied, wire breakage or failure may be caused.
[INSTALLATION PRECAUTIONS]
CAUTION
• Use the module in an environment that meets the general specifications
contained in this manual. Using this module in an environment outside
the range of the general specifications could result in electric shock, fire,
erroneous operation, and damage to or deterioration of the product.
• Do not directly touch the module's conductive parts.Doing so could
cause malfunction or trouble in the module.
[WIRING PRECAUTIONS]
DANGER
• Perform installation and wiring after disconnecting the power supply at
all phases externally. If the power is not disconnected at all phases an
electric shock or product damage may result.
CAUTION
• Perform correct wiring for the module according to the product's rated voltage
and terminal arrangement. Connecting to a power supply different from rating
or miss-wiring may cause fire, product failure or malfunction.
• Make sure foreign objects do not get inside the module, such as dirt and wire
chips. It may cause fire, product failure or malfunction.
• Do not short-circuit the 24G and +24V terminals. It may result in fire, product
failure or malfunction.
• Attach a warning label (hazard symbol 417-IEC-5036) concerning the electric
shock to the location.
[STARTING AND MAINTENANCE PRECAUTIONS]
DANGER
• Do not touch the terminals when the power is ON. It may cause an electric
shock or malfunction.
• Perform cleaning the module after turning OFF the all external power supply
for sure. Failure to do so may cause failure or malfunction of the modules.
CAUTION
• Do not disassemble or modify the module. Doing so may cause failure,
malfunction, injury, or fire.
• The module case is made of resin; do not drop it or subject it to strong shock.
A module damage may result.
• Make sure to switch all phases of the external power supply OFF before
installing or removing the module to/from the panel. Failure to do so may
cause failure or malfunction of the modules.
[DISPOSAL PRECAUTIONS]
DANGER
• When disposing of this product, treat it as industrial waste.
[TRANSPORTATION AND MAINTENANCE PRECAUTIONS]
CAUTION
• During transportation avoid any impact as the module is a precision
instrument. Doing so could cause trouble in the module.
• If is necessary to check the operation of module after transportation, in case
of any impact damage.
G G G G Notification of CE markingG G G G
This notification does not guarantee that an entire mechanical module produced
in accordance with the contents of the notification comply with the following
standards. Compliance to EMC standards of the entire mechanical module
should be checked by the user / manufacturer.
Standards with which this product complies
Type : Programmable Controller (Open Type Equipment) Remote I/O module
Models : Products manufactured from November 1st, 2002.
Electromagnetic Compatibility Standards
Remark
(EMC)
EN61000-6-4:2001
Compliance with all relevant
Electromagnetic compatibility
aspects of the standard. (Radiated
-Generic standards - Emission standard for
Emissions and Mains Terminal
Industrial environment
Voltage Emissions)
EN61131-2:1994 Programmable controllers
Compliance with all relevant
/A11: 1996 -Equipment requirements and
aspects of the standard. (RF
tests
Immunity, Fast transients, ESD and
/A12: 2000
Damped oscillatory wave)
For more details please contact the local Mitsubishi Electric sales site.
- Notes For compliance to EMC regulation.
It is necessary to install the CL1 series module in a shielded metal control panel.
1.
Outline of Product
This product is a cable type output module connected to CC-Link/LT.
This product has two output points (transistor output).
Connector dedicated
to CC-Link/LT
(sold separately)
Output
Lamp
equipment
2.
Name and Setting of Each Part
Flat cable dedicated
to CC-Link/LT
Switch cover
DIP switch
(Make sure to attach the
(Remove the switch cover
switch cover after setting
when setting the DIP switch.)
the DIP switch.)
Attach it with
DIP switch assignment
this area facing
40 20 10 8 4 2 1
HLD
upward.
Status indicator LEDs
Output operation indicator LED
LED name
Operation
Output is ON: Lit
PW
Lit while the
Output is OFF: Extinguished
power is supplied.
L RUN
Lit while normal
operation is
Flat cable for I/O
Blue
White
executed.
Black
Brown
Name
Description
PW
ON while the power is supplied.
Status indicator
LED
L RUN ON while normal operation is executed.
ON while the output is ON.
Extinguished while the output is OFF.
Output operation
indicator LED
0
1
Y0 output operation
Y1 output operation
indicator LED
indicator LED
24G
Flat cable
DB
Connector for CC-Link/LT communication line/
dedicated to CC-
module power supply
DA
Link/LT
+24V
Blue
24G
Black
Y0
Flat cable for I/O
White
Y1
Brown
+24V
Set the 10's digit of the station No. using "STATION NO. 10",
"STATION NO. 20" and "STATION NO. 40". Set the 1's digit of
the station No. using "STATION NO. 1", "STATION NO. 2",
"STATION NO. 4" and "STATION NO. 8".
Factory default = All bits are OFF
Make sure to set the station No. in the range from 1 to 64.
DIP switch
Example: When setting the station No. to "32", set the
DIP switch as follows.
10's digit
1's digit
Station
No.
40
20
10
8
4
2
32
OFF
ON
ON
OFF
OFF
ON
Name
Description
Holds the output (when an error has occurred).
DIP switch
HLD
ON: Holds the output.
OFF: Clears the output.
3.
Cautions on Handling
3.1 Handling of flat cable for I/O
The cable length from the module to a sensor shall be within 3m(9'10").
Measure the cable outside the module, and confirm that the driving voltage
for the used sensor is assured.
• Output
Crimp-style connection device with
insulator or closed end connection
device
If the diameter of the output equipment connection cable is equivalent to
the diameter of the flat cable for I/O of this module, connectors dedicated to
CC-Link/LT can be used for connection.
Connector dedicated to CC-Link/LT
Wire diameter: AWG18 (34/0.18)
3.2 Handling of cable
Do not bend the cable within 30mm(1.19") from the module.
30mm(1.19")
Use a crimp-style terminal in a status in which no force is applied on the
cable.
3.3 Mounting with the CL1-HLD (module holder)
Refer to the figures below for details on mounting or removing the remote
I/O module when used with the CL1-HLD.
Mount
Dismount
CL1-HLD
1)Fit the remote
I/O module in
b)
a corner of the
CL1-HLD.
2)Press down b)
while holding
Remote
I/O
a).
module
a)
1)Insert a screwdriver into either a, b, or c.
2)Pry the remote I/O module from the
holder using the screwdriver.
1
OFF
Lamp,
solenoid, etc.
Output
equipment
Output
equipment
30mm(1.19")
a
b
c
d

Advertisement

loading

Summary of Contents for Mitsubishi CL1Y2-T1D2S

  • Page 1 • The module case is made of resin; do not drop it or subject it to strong shock. A module damage may result. the module properly. These precautions apply only to Mitsubishi equipment. Refer to the user’s • Make sure to switch all phases of the external power supply OFF before Switch cover manual of the CPU module to use for a description of the PLC system safety installing or removing the module to/from the panel.
  • Page 2 Number of stations category (Category II or less)(*4) Mitsubishi will not be held liable for damage caused by factors found not to be the 4-, 8- or 16-point mode: 1 station occupied cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi...
  • Page 3 (Category II or less)(*4) 4-, 8- or 16-point mode: 1 station Mitsubishi will not be held liable for damage caused by factors found not to be the occupied cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi...