Mitsubishi A8GT-50KBF User Manual
Mitsubishi A8GT-50KBF User Manual

Mitsubishi A8GT-50KBF User Manual

External i/o interface module
Hide thumbs Also See for A8GT-50KBF:

Advertisement

Quick Links

External I/O Interface Module
Thank you for choosing the MELSEC-GOT Series.
To ensure correct use of this equipment, please read this manual
carefully before operating it.
MITSUBISHI Graphic Operation Terminal
A8GT-50KBF
User's Manual
MODEL
MODEL
CODE
IB(NA)-68908-C(0406)MEE
(Hardware)
A8GT-50KBF-U
1DM053

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi A8GT-50KBF

  • Page 1 A8GT-50KBF External I/O Interface Module User’s Manual (Hardware) Thank you for choosing the MELSEC-GOT Series. To ensure correct use of this equipment, please read this manual carefully before operating it. MODEL A8GT-50KBF-U MODEL 1DM053 CODE IB(NA)-68908-C(0406)MEE MITSUBISHI Graphic Operation Terminal...
  • Page 2: Safety Precautions

    Also pay careful attention to safety and handle the module properly. These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device. Refer to the user’s manual of the CPU module to be used for a description of the PLC system safety precautions.
  • Page 3 [INSTALLATION PRECAUTIONS] DANGER ! When installing and removing this module from the GOT main module be sure to shut off the power at all external switches. If all the switches are not turned off, the module could be damaged or malfunction. ! When connecting the bus connection cable to this module be sure to turn off the switch to all external power switches to the GOT and PC CPU.
  • Page 4 [STARTING AND MAINTENANCE PRECAUTIONS] DANGER ! Do not change the switch setting while power is on. ! Switch all phases of the GOT external power supply off before cleaning. Not doing so could result in electric shock. CAUTION ! Never disassemble or modify the module. This may cause breakdowns, malfunctioning, injury, and/or fire.
  • Page 5 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 6: Table Of Contents

    CONTENTS 1. Overview......................1 2. Components Including in the Package ............1 3. Specifications ....................2 4. System configuration ..................7 5. User-fabricasted connection cables............... 9 5.1 Connection cable ..................9 5.2 Wiring diagrams ..................13 6. Parts Identifcation..................17 7.
  • Page 7: Overview

    1. Overview This user's manual gives the specifications, system configurations, parts identifi-cation, installation procedure and outline dimensions of the A8GT- 50KBF type external I/O unit (referred to as the external I/O unit). The external I/O unit is fitted to the A956WGOT/A95*GOT/A85*GOT (referred to as the GOT) to receive up to 8/64 points of inputs and provide up to 16 points of outputs.
  • Page 8: Specifications

    3. Specifications Input Specifications Input system Dynamic scan Number of input points 8/64 points Isolation system Photocoupler isolation Rated input voltage 12VDC 24DVC Rated input current Approx. 4mA Approx. 9mA Operating voltage range 10.2 to 26.4VDC (ripple percentage within 5%) Max.
  • Page 9 I/O Specifications External connection system 40-pin connector Applicable wire size 0.3mm2 Operation indicator None 12/24VDC Voltage*3 External (10.2 to 26.4V, ripple percentage 5% or less) supply power 1.65A for external output Current 0.05A for internal consumption only Fuse rating*2 2.0A fuse, unreplaceable Internal current consumption 0.1A Weight 250g(0.55lb)
  • Page 10 External Connector Pin-Outs View from the unit front Connector used: Fujitsu's FCN-365P040-AU B1 B2 B3 B4 B5 B6 B7 B8 B9 B10B11B12B13B14B15B16B17B18B19B20 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10A11A12A13A14A15A16A17A18A19A20 Pin Numbers and Signal Names of External Connector Pin Number Signal Name Pin Number...
  • Page 11 External Connection Diagram (1) (8-point inputs, 16-point outputs) Pin number Internal control circuit XSCN0 Internal XSCN1 control Internal XSCN2 circuit scan is XSCN3 XSCN4 made at XSCN5 1/8 duty. XSCN6 XSCN7 Internal control circuit YD10 YD11 YD12 YD13 YD14 YD15 A17,B17,A18 Fuse-blown B18,A19...
  • Page 12 External Connection Diagram (2) (64-point inputs, 16-point outputs) Pin number Internal Input terminals control circuit Internal XSCN0 XSCN1 control Internal XSCN2 circuit scan is XSCN3 XSCN4 made at XSCN5 1/8 duty. XSCN6 XSCN7 Internal control circuit YD10 YD11 YD12 YD13 YD14 YD15 A17,B17,A18...
  • Page 13: System Configuration

    4. System Configuration (1) System configurations and connection conditions The following system configuration assumes connection of a printer. The numbers ( ) given in the system configurations denote the numbers ( ) in "(2) System equipment". Refer to these numbers when you want to confirm the types and applications.
  • Page 14 I/O equipment. Type Image Applocation External I/O GOT unit interface unit A956WGOT, External I/O equipment-connected A95*GOT, A8GT-50KBF A85*GOT Ten-key panel A8GT-TK FP5-MD41-A (Kanaden Corp. make), Operation panel*1 FP5-MD41-B (Kanaden Corp. make) Connector terminal block conversion A6TBY36-E, A6TBY54-E...
  • Page 15: User-Fabricasted Connection Cables

    5. User-fabricated Connection Cables The following is the way of fabricating the connection cable which can be fabricated by the user: 5.1 Connection cable (1) Cable for connection between external I/O unit and original operator panel Fabricate the connection cable in accordance with the following wiring diagram, parts diagram and assembly drawing: (Maximum cable length: 20m (16.4feet)) (a) Connection diagram...
  • Page 16 (b) Parts list Number Name Type Maker Mitsubishi 1) 2) Connector (with cover) A6CON1 Electric Connector FCN-361JO40-AU Fujitsu Connector cover FCN-360CO40-B Pair shielded cable UL 2464 AWG26 or equivalent FG wire UL 1015 AWG14 or equivalent  Wires for connection...
  • Page 17 (2) Cable for connection between external I/O unit and terminal block conversion unit. Fabricate the connection cable in accordance with the following wiring diagram, parts diagram and assembly drawing: (Maximum cable length: 10m (32.79feet)). (a) Connection diagram Original operator External I/O panel side unit side Signal...
  • Page 18 (b) Parts list Number Name Type Maker Mitsubishi 1) 2) Connector (with cover) A6CON1 Electric Connector FCN-361JO40-AU Fujitsu Connector cover FCN-360CO40-B Pair shielded cable UL 2464 AWG26 or equivalent  FG wire UL 1015 AWG14 or equivalent (c) Assembly 1) 2)
  • Page 19: Wiring Diagrams

    5.2 Wring diagrams (1) Wiring diagram for use between external I/O unit and connector terminal block conversion unit (a) For use of the connector terminal block conversion unit (A6TBY36-E) Cable for connection between external I/O unit and connector terminal block A8GT-70KBF conversion unit Shield...
  • Page 20 (b) For use of the connection terminal block conversion unit (A6TBY54-E) Cable for connection between external I/O unit and connection terminal block A8GT-70KBF conversion unit Shield XSCN0 XSCN1 XSCN2 XSCN3 XSCN4 XSCN5 XSCN6 XSCN7 A6TBY54-E YD10 YD11 YD12 YD13 YD14 YD15 DC12/24V DC12/24V...
  • Page 21 (2) Connection of external inputs and external outputs to the connector terminal block conversion unit. (a) For use of the connector terminal block conversion unit (A6TBY36-E) Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load...
  • Page 22 (b) For use of the terminal block conversion unit (A6TBY54-E) Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load...
  • Page 23: Parts Identifcation

    6. Pates Identification A8GT-50KBF Name Description I/O cable connection Interface for connection of the I/O cable interface Unit fixing screws Screws used to fix the unit to the GOT Connector used to plug the unit to the Connector GOT. ...
  • Page 24: Installation Procedure

    7. Installation Procedure Install the unit to the GOT in the following procedure: (1) Thread External I/O unit mounting screw holes in the control box or the like. (2-φ3.5 mounting holes) The External I/O unit’s GOT connection cable is 50cm long. Install the External I/O unit within this distance so that the GOT-end connector of the cable may be fitted into the GOT’s connector.
  • Page 25: Outline Dimension Drawing

    8. Outline Dimension Drawing A8GT-50KBF MITSUBISHI 42.6 (1.68) 92 (3.62) (0.13) (0.37) 105 (4.13) 44 (1.73) Unit: mm (inch)
  • Page 28: Manuals

    Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi;...

Table of Contents