Avalue Technology SID-21W04 Quick Reference Manual page 8

21.5" pcap panel pc w/atom j3455 soc
Table of Contents

Advertisement

SID-21W04
Mechanical
Power Type
Power Connector
Type
Dimension
Weight
Color
Fanless
OS Support
Reliability
EMI Test
Safety
Dust and Rain Test
Random Vibration
Test
Sine Vibration Test
(Non-operation)
Packing Vibration
Test
Mechanical Shock
Test
8 SID-21W04 Quick Reference Guide
12V~24V wide voltage DC input
DC jack
535x329.31x56.6 mm
8.7 kg
Metallic
Yes
2019 Win 10 / Ubuntu 20.04
CE/FCC Part 15, Subpart B
IEC-62368-1 & EN62368-1
Front Panel IP65
Test Standard: Reference IEC60068-2-64 Testing procedures
1. System condition: Operation mode
2. PSD: 0.00454G²/Hz , 1.5 Grms
3. Test Frequency : 5-500Hz
4. Test Axis : X,Y and Z axis
5. Test time: 30 minutes per each axis
Storage : eMMC
Test Standard: Reference IEC60068-2-6 Testing procedures
1. System condition : Non-Operating mode
2. Test Acceleration : 2G
3. Test frequency : 5~500 Hz
4. Sweep:1 Oct/ per one minute. (logarithmic)
5. Test Axis : X,Y and Z axis
Test time :30 min. each axis
1. PSD: 0.026G²/Hz , 2.16 Grms
2. Non-operation mode
3. Test Frequency : 5-500Hz
4. Test Axis : X,Y and Z axis
5. 30 min. per each axis
6. IEC 60068-2-64 Test:Fh
Test Standard: Reference IEC60068-2-29 Testing procedures
1. System Condition: Operation
2. Wave form: Half-Sine wave
3. Acceleration: Rate: 10g
4. Duration: Time: 11ms
5. No. of Shock: Z axis 300 times
6. Test Axis: Z axis

Advertisement