Base Unit; Control Pcb - Canon imageFORMULA DR-M140 Service Manual

First edition
Hide thumbs Also See for imageFORMULA DR-M140:
Table of Contents

Advertisement

CHAPTER 3 DISASSEMBLY & REASSEMBLY
II. BASE UNIT

1. Control PCB

1) Remove the bottom cover and the
document feed tray.
(Page 3-2)
2) Remove
the
self-tapping) and turn the control PCB
(with mounting plate) upside-down. Then,
remove the connected connectors.
Figure 3-201
Figure 3-202
3) Remove the 6 screws
remove the control PCB
mounting plate.
3-4
2
screws
(M3,
1
(M3xL4) and
1
from the
2
COPYRIGHT © CANON ELECTRONICS INC. 2011
2
Notes on assembling
You should insert the connector straight
and all the way in. Be careful when
handling the reading unit connector
because it is thin.
Furthermore, although the lengths of the
upper and lower cables of the reading
unit differ to suit the positions of the
connectors, the connectors are the
same, and you should not connect them
incorrectly.
Figure 3-203
Upper
Lower
(J111)
(J110)
Figure 3-204
CANON DR-M140 FIRST EDITION

Advertisement

Table of Contents
loading

Table of Contents