Table Of Contents - Fetco TBS-2111 User’s Manual & Operator Instructions

Hot tea brewer extractor touch screen m
Table of Contents

Advertisement

TABLE OF CONTENTS

OPERATIONAL DESCRIPTION .................................... 3
BASIC SCREENS .......................................................... 3
PROGRAM ..................................................................... 6
GENERAL ....................................................................... 8
INPUTS ........................................................................... 8
Specifications and Requirements
TBS-2111-Capacities & Measurements
Brewer
Height
733 mm
TBS-2111
29 inch
TBS-2111-Dimensions & Utility Connections
Note: dimensions in parenthesis are in millimeters
TBS-2111-Electrical Configurations
Configuration
Heater
Code
Configuration
T211151
1 X 1.7kW
T211191
1 X 3KW
T211192
1 X 2.3KW
Please see wiring diagrams located in back pages for installation notes.
TBS-2111-Water Requirements
Water Connection: Inlet: 3/8 inch male flare fitting
Mains Pressure:
Minimum Flow Rate:
All commercial hot water dispensers to be supplied with filtered water from mains
The following are the factory settings-and ranges of variables that are adjustable:
Brew volume: 6 liter Batch: (default all recipes: 4 liters brew+34% bypass)
RANGE [0.50-6.00 liter BREW] [0-40% BYPASS]
*Brew volume per hour based on factory default of 11:43 minutes/6 liter 30 liters or 8 gallons/hour
Total Brew Cycle-Factory setting: 10:52 minutes [6 minute brew time+1.5 minute drip delay+2minute bypass]
RANGE [1:00-12:00 minute BREW] [0:30-12:00 minute BYPASS DELAY]
Temperature Control-as set by factory: 90°C inside hot water tank (at sea level).
-RANGE User selectable: 77-97°C/170°-207°F
-Brew Temperature may be individually set for each of the eight recipes.
Coffee Filter Size: 15" X 5 ½ "- standard FETCO # F001
FETCO TBS-2111 Hot Tea Brewer with Bypass (hot water bypass)
Width
Width
No hot water
One hot water
faucet
faucet
229 mm
292 mm
9 inch
11.5 inch
Voltage
Phase
100-120
single L, N, G
200-240
single
200-240
single L,N,PE
0.31-0.517 mPa 0.34MPa/50PSI preferred (45-75 psig ).
5.7 liter/minute (1½ gpm). Optimal water hardness between 125-250 TDS (6-13 grain)
HOW TO CALIBRATE THE FLOW RATE ................... 10
OTHER ......................................................................... 13
ERROR CODES ........................................................... 14
Parts Drawings And Wiring Diagrams .......................... 18
Width
Two hot water
Depth
faucets
356 mm
502 mm
14 inch
20 inch
Electrical
Wires
Connection
NEMA 5-15
Shuko
2+G
cord and plug
Australian
cord and plug
2
Empty
Filled
Hot Water Tank
Weight
Weight
14.4kg
26.3kg
32 lb
58 lb
Drawing number 1201.00041.00
KW
Amp Draw
1.3-1.8
12.3-14.7
4.4 gal/16.5 liters
3.1
10.8-12.9
30 liters/8 gallon
2.5
19.8
30 liters/8 gallon
Capacity
11.9 liter
3.1 gallon
Brew
Per hour*

Advertisement

Table of Contents
loading