Control Mcu(Rl78) - Renesas RTK0EE0007D03001BJ User Manual

Plc modem lsi r9a06g037 bcpx3 evaluation kit j80d2
Table of Contents

Advertisement

BCPX3 Evaluation Kit J80D2 RTK0EE0007D02001BJ

Control MCU(RL78)

3.2.5
The RL78 MCU board is equipped with RL78 for PLC control. The following table shows the control MCU
terminal connection information. For unused pin settings, set the ports to "Input" since the signals connected
to CPX3 have the pin assignments on the CPX3. Also, use the MCU on-chip pull-up function to set other
signal terminals.
PIN No.
Pin name of RL78
1
P60/SCLA0
2
P61/SDAA0
3
P62
4
P63
5
P31
6
P75
7
P74
8
P73
9
P72
10
P71
11
P70
12
P30
13
P50
14
P51
15
P17
16
P16
17
P15
18
P14
19
P13
20
P12
21
P11
22
P10
23
P146
24
P147/ANI18
25
P27
26
P26
27
P25
28
P24
29
P23
30
P22
31
P21
32
P20
33
P130
34
P01/RXD1
35
P00/TXD1
36
P140
37
P120
38
P41
39
P40/TOOL0
40
RESET
41
P124/XT2
42
P123/XT1
43
P137
44
P122/X2
45
P121/X1
46
REGC
47
VSS
48
VDD
R30UZ0099EJ0100 Rev.1.00
Oct 01, 2017
Table 3-9 RL78 MCU connection table
Connection
O
CN18-4
O
CN18-3
O
LED9
O
LED10
I/O
CN18-16
I/O
CN18-15
I/O
CN18-8
I/O
CN18-13
I/O
CN18-11 and CN19-6
I/O
CN18-12 and CN19-8
I/O
CN18-10 and CN19-9
I/O
CN19-10
I/O
CN19-15
I/O
CN19-2
I/O
CN19-14
I/O
CN19-13
O
SROM_C
I
SROM_DQ1
O
SROM_DQ0
I/O
CN19-3
I/O
CN19-4
I/O
CN19-2
O
SROM_CS
I/O
CN18-2
I
DIP SW8
I
DIP SW7
I
DIP SW6
I
DIP SW5
I
DIP SW4
I
DIP SW3
I
DIP SW2
I
DIP SW1
O
CN19-1
I
CN19-16
O
CN19-17
I/O
CN18-16
I
-
I/O
CN19-12
I
CN17-5
I
I
I
I
-
I
XTL 20MHz
I
XTL 20MHz
-
0.47uF capacitor
-
GND
-
3.3V
3.Interface Specifications
Notes (recommended setting when not in use)
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
Select the input port when not in use
-
-
-
Page 39 of 46

Advertisement

Table of Contents
loading

Table of Contents