Casio IT-G500 Service Manual page 12

Handheld terminal
Hide thumbs Also See for IT-G500:
Table of Contents

Advertisement

Item
CMOS Imager
Type
(model dependent)
Aimer
Resolution
Readable Distance From a distance of a few millimetres to several metres,
Reading
Symbologies
<Power Supply/Data Communication Terminals>
Pin No.
Name
1
V CRADLE
2
D–
3
D+
4
V BUS
5
USB_ID
6
GND
CMOS Imager, resolution 832 x 640 px, monochrom
Laser beam 650 +10/-5 nm, 1 mW or less
1D codes: 0,127 mm, 2D stacked-codes: 0,169 mm,
2D matrix-codes: 0,191 mm
depending on the size and print quality of the code
1D codes: EAN8, EAN13, UPC-A/E, Codabar (NW-7),
CODE32, CODE39, CODE93,
CODE128/GS1-128 (UCC/EAN128), ITF, MSI, ISBT,
GS1 DataBar Omnidirectional, GS1 DataBar Truncated,
GS1 DataBar Limited, GS1 DataBar Expanded
2D stacked-codes: PDF417, Micro PDF, Composite,
Codablock F, GS1 DataBar Stacked,
GS1 DataBar Stacked Omnidirectional,
GS1 DataBar Expanded Stacked
2D matrix-codes: Aztec, DataMatrix, Maxicode, QR Code,
Micro QR
1 2 3 4 5 6
Function
Power supply/charge to IT-G500
USB D–
USB D+
USB power control signal
USB host/client switching
GND
– 5 –
Specifi cations
Input/Output
IT-G500
IN/OUT
IN/OUT
IN/OUT
IN

Hide quick links: